Mounting on Metallic Doors
3
6
4
9
5
17.0 mm
2
6
17.0 - 17.5 mm
min. 18 mm
max. 26 mm
Installation measures for GAT NET.Lock 7000 and Bolt Set
During the mounting, please pay particular attention to the following points:
- The door thickness must be between 18 and 26 mm (see figure).
- When the door is pressed shut, the gap between the bolt set (2) and the
front of the GAT NET.Lock 7000 must not be exceed 0.5 mm. Ideally the
bolt set should touch the front of the lock.
- The middle of the door shackle (4) must be 1 mm higher than the middle
of the door shackle opening in the GAT NET.Lock 7000. This ensures
the door's ability to close even if the door position is modified 3 mm
downwards or 1 mm upwards (tolerance ±2 mm).
Cut-outs in the Locker Door
8
9
Valid as from September 27
4
DB_GAT-NET-Lock7000--EN_20.indd • Art.Nr.: 573734
1
3
3
74.0 mm
Inside of Locker
1.7
Inside of Locker
2013 • Technical data subject to modifications without notice!
th
Locker Door
(Front view without lable carrier)
1
6
3
2
3
7
3
6
15.1 mm
Locker Door (Front view)
9
8
80.4
6
LED
6
13.1
63.4
0.8
17.6
46.6
65.9
4 x holes for screws,
Ø 3.6 mm, see step 7
on page 5
All measures in mm.
(Front view with lable carrier)
10
7
1. GAT NET.Lock 7000
2.
GAT NET.Lock Bolt Set 7200
3. Mounting screws for GAT NET.Lock 7000
4.
Door shackle
5.
Door contact
6. Mounting screws for bolt set
7.
LED position
8.
Cut-out for GAT NET.Lock Bolt Set 7200
9. Cut-out for label carrier
10. Label carrier
On the inside and outside walls of the
locker door cut-outs must be made in
order to mount the GAT NET.Lock Bolt Set
7200 and the label carrier. The mounting
procedure is described on the next page.
83.6
The measurements for the cut-outs are
79.1
shown in the figure to the left.
11.1
6.6
Lock bottom edge
www.gantner.com
Locker Door
(Front
12
7