appliance power rating. Refer to the
Technical data chapter.
The rating plate is located below the
surface of the casing.
The appliance is supplied with a connection
cable. The cable must be provided with a
proper plug, which supports the load
marked on the identification plate. Refer to
the Technical data chapter.
The plug has to be fitted in a proper socket.
If connecting the appliance directly to the
electric system, it is necessary that you
install a double pole switch between the
appliance and the electricity supply, with a
minimum gap of 3 mm between the switch
contacts. The double pole has to be of a
type suitable for the required load in
compliance with the current rules.
The connection cable has to be placed in
order that, in each part, it cannot reach a
90 °C temperature. The blue neutral cable
must be connected to the terminal block
marked with "N". The brown or black phase
cable, fitted in the terminal block contact
marked with "L", must always be connected
to the live phase.
Electrical Requirements
You can check the parameters of
adjustment setting for this
appliance on the rating plate.
Refer to the Technical data
chapter.

Gas connection

Warning! Refer to Safety
chapters.
Caution! Information for
authorised installer only.
The manufacturer declines any
liability if these safety measures
are not observed.
This hob is designed to be connected to a
220-240 V 50-60 Hz AC electrical supply.
Before switching on, make sure the
electricity supply voltage is the same as that
indicated on the hob rating plate. The
rating plate is located below the surface of
the casing.
The hob is supplied with a 3 core flexible
supply cord.
Upon completion there must be no cut, or
stray strands of wire present and the cord
clamp must be secure over the outer sheath.
Replacement of the connection cable
Warning! Only the After Sales
Service Provider or qualified
electrician can replace the
electric cable.
If the connection cable must be replaced,
only a type H03V2V2-F T90 cable must be
used. The cable section must be suitable to
the voltage and the working temperature.
The yellow and green earth wire must be
approximately 2 cm longer than the brown
or black phase wire.
Connection to main pipe
Warning! This appliance is not
connected to a combustion
products evacuation device.
16