Gantom JUNI DMX GP285 사용자 설명서 - 페이지 2
{카테고리_이름} Gantom JUNI DMX GP285에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Gantom JUNI DMX GP285 15 페이지.
POWER AND WIRING REQUIREMENTS
The Gantom Juni DMX has a maximum wattage of 11W and an operating voltage range of 12-24VDC.
The Gantom Juni DMX includes a single locking connector which combines both power and data into
one compact cable. This connector is compatible with our Gantom Pro Cable System, including our G8
Power/Data Distribution Box. A single cable for power and data greatly simplifies installation and the
locking connector gives a secure connection for long term use. This makes the Gantom Pro Cable
System ideal for permanent installations. For more information on this system, please visit
https://www.gantom.com/accessories/gantom-pro-cable/
BARE WIRE PINOUT
+
RED
Power
-
BLUE
D+
GREEN
DMX signal
D-
YELLOW
COM
BLACK
Note: all fixtures must be installed with the low voltage supply power OFF. Hot
plugging (connecting to a live power supply) is not supported.
Hot plugging a fixture into a system with a running power supply will increase the load on the power
supply, which can generate voltage spikes that more than double of the standard input voltage. This
causes an out-of-spec and out-of-warranty voltage condition which may result in damage to the fixture.
While Gantom fixtures have internal protections against voltage spikes, it is recommended that
installers handle them with care to prevent these spikes from happening in the first place.
Installing all fixtures in the system before turning on power to the low voltage
power supply assures that the power supply has a "soft start" which is free from
harmful voltage spikes.
Gantom Juni DMX User Guide
Version 1.0 – 3/25/2021