Ganz C-AllView 설치 관리자 매뉴얼 - 페이지 8

{카테고리_이름} Ganz C-AllView에 대한 설치 관리자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Ganz C-AllView 20 페이지.

Ganz C-AllView 설치 관리자 매뉴얼
Camera telemetry settings
Depending on the chosen protocol, telemetry control signals may be fed to the
camera either via the primary co-axial video link cable or through the twisted pair
cables that are included within the composite cable.
Note: Due to limitations or software changes within some protocols, it is not always
possible to implement all of the camera's features.
All settings related to telemetry control are configured using two banks of switches
(S1 and S2) located behind a removable panel within the hub of the camera.
To access the switches, remove the two retaining screws and remove the panel:
Note: In all switch setting tables, a dash (-) means the corresponding switch is Off.
Device ID address (block S1, switches 1 to 8)
For protocols which use RS485 control signals via the twisted pair link within the
camera's composite cable, you can determine the device ID address for the camera.
Note: These settings are ignored for protocols that use the primary video coaxial
cable to transfer telemetry signals.
D evice ID
S1-1 S1-2 S1-3 S1-4 S1-5
0
-
1
On
2
-
3
On
4
-
5
On
6
-
7
On
8
-
9
On
10
-
11
On
12
-
13
On
14
-
-
-
-
-
-
-
On
-
-
On
-
-
-
On
-
-
On
-
On
On
-
On
On
-
-
-
On
-
-
On
On
-
On
On
-
On
-
On
On
-
On
On
On
On
On
S2
S1-6
S1-7
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
S1