Avantco 178A12FHC 사용자 설명서 - 페이지 5
{카테고리_이름} Avantco 178A12FHC에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Avantco 178A12FHC 9 페이지. Reach-in refrigerators & freezers
Avantco 178A12FHC에 대해서도 마찬가지입니다: 사용자 설명서 (8 페이지)
Temperature Controls
Adjusting the Temperature
• Your new refrigerator or freezer is already factory-set to run at optimum temperatures for food safety and
should require no adjustments.
• Refrigerators are set to cycle between a minimum temperature of 33°F and a maximum temperature of 40°F.
• Freezers are set to cycle between a minimum temperature of -5°F and a maximum temperature of 2°F.
• Adjusting the temperature changes the minimum temperature at which your unit will run. Your unit will not run
constantly at this setting. To change it, follow these instructions:
Digital Control Units
1. Hold "SET" for 1 second. The display will flash the
current minimum temperature.
2. Use the arrow buttons to adjust the minimum
temperature you'd like the unit to run at.
3. Press "SET" again to save your settings.
Always remember to calculate the differential if you
change the minimum temperature setting. The cabinet
temperature will fluctuate up to 7°F over your set
minimum temperature as the compressor runs and
shuts off. Setting the temperature too high will result
in unsafe maximum temperatures and possible health
code violations.
Operation
Defrost System
Automatic Defrost Cycle
• Refrigerator coils are kept below the freezing point (32°F).
• During compressor downtime, the evaporator fan continues to circulate air through the evaporator coil.
This air circulation raises the coil temperature above the freezing point, melting any accumulated frost.
• Run-off water is drained into the evaporator pan and evaporated.
• Automatic defrost timers initiate at pre-set intervals and for a pre-determined duration.
User Manual
Reach-In Refrigerators & Freezers
Freezers (older models)
Refrigerators & Newer Freezers
www.AvantcoRefrigeration.com
5