Green Mountain GMHB227 사용자 정보 설명서 - 페이지 5

{카테고리_이름} Green Mountain GMHB227에 대한 사용자 정보 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Green Mountain GMHB227 9 페이지.

3.1 USER CONTROLS

BUTTON Explanation:
DHW temperature adjustment
LEFT KNOB
(CW to increase the temperature and CCW to decrease it)
Heating water temperature adjustment
RIGHT KNOB
(CW to increase the temperature and CCW to decrease it)
Boiler operating information
Deaeration (Long Push)
Comfort function (Short Push)
Off – Reset – Exit menu/functions
SYMBOL Explanation:
Off: Heating and DHW disabled
(only boiler frost protection is active)
Ignition fault
Boiler/system water pressure low
Call a qualified service technician
Manually resettable fault
Fault in progress
3.2 CENTRAL HEATING SYSTEM PRESSURE
Regularly check the pressure displayed on the pressure
gauge "B" is between 14.50 and 21.76 psi (1.0 - 1.5 bar),
with the boiler cold.
If the pressure is less than 14.50 psi, or higher than 21.76
psi
call an authorized SERVICE technician.
3 - CONTROL
(DHW)
Burner lit
DHW operating mode enabled
Heating mode enabled
Programming menu
Boiler information menu
Set unit of measurement
Safety Relief Valve
Do not use plastic
pipe.
Check Local Codes For
Maximum Distance To Floor
5
(CH)
(SI/US)
Pressure
PN 240012364 Rev. A [08/31/18]
"B"
Gauge