Troubleshooting
Problem
Condensing Units Run
for Long Periods of Time
Condensation is
Collecting on the
Cabinet and/or Floor
www.AvantcoRefrigeration.com
16
User Manual
Refrigerated Prep Tables
Possible Solution
Excessive amount of warm product placed in cabinet
Allow adequate time for product to cool down
Prolonged door opening or door ajar
Ensure doors are closed when not in use
Avoid opening doors for long periods of time
Door gasket(s) not sealing peroperly
Ensure gaskets are snapped in completely
Remove gasket and replace if necessary
Dirty condenser coil
Clean the condenser coil
Evaporator coil iced over
Unplug unit and allow coil to defrost
Make sure thermostat is not set too cold
Ensure that door gasket(s) are sealing properly
Gasket is not sealing properly
Clean, repair, or replace the gasket as necessary
Relative humidity is above 60%
Move unit to area below relative humidity or lower humidity level