Ganz zn-dn9922nha 사용 설명서 - 페이지 8

{카테고리_이름} Ganz zn-dn9922nha에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Ganz zn-dn9922nha 12 페이지. Zn-d9000 series network mini dome cameras

Ganz zn-dn9922nha 사용 설명서

Connecting the cables

Connect the power cable and the LAN cable.
Attention
Check if the power supply is "OFF."
1
Connecting the power supply cable.
1
Connect the power cable (plug) included to the power source. In
the case of 12 V DC, connect the red cable to 12 V DC and the
black cable to the GND.
2
Connect the power cable (plug) connected in Step 1 above to the
power cable (jack) of the camera body.
Attention
When connecting the power source directly to the power input terminal of
the camera body without using the power cable (plug) included, be sure to
use a heat-resistant cable (resistant to the temperature higher than 75°C).
When connecting the 12 V DC power directly to the power input terminal
of the camera body without using the power cable (plug) included, be sure
to align "+12 V DC" with "GND" that are displayed near the terminal of the
board.
2
Connecting the LAN cable.
Connect the LAN cable to the LAN cable (jack) of the camera body.
When the LAN cable is connected, the LAN cable
connection confi rmation LED (orange) lights up. The
LED (yellow) or (green) is fl ashing according to Receive
and Transmit.
Connection confi rmation (Orange)
DC12V
RED
BLACK
Receive (Yellow)
Transmit (Green)
EG-8
Attention
When the power is supplied at the same time from the PoE power source
and the power cable, the power cable line is used.
When the PoE power source is used, the connection of the power cable is
not required.
Use CLASS 2 power supply when you use 24 V AC.
Be sure to check that the cables are connected correctly before turning the
power on.
Turning on the power when the cables are connected with incorrect polarity
may damage the camera.
Be sure to use a LAN cable of category 5 or above.
Connection of I/O cables
When using an alarm and/or a speaker,
connect the I/O cables to the I/O cable
terminals provided on the camera body.
Wiring of I/O cable
1 (Brown) Input
2 (Red) GND
3 (Orange) Output
4 (Yellow) Output
Attention
"1" is an alarm input terminal with no-voltage make-contact input (3.3 V DC
pull-up resistor built-in, short circuit current is 0.4 mA).
"3" and "4" are alarm output terminals with contact output (30 V DC, 1 A
- 125 V AC 0.3 A).
5 (Green) Speaker (Output)
6 (Blue) GND
7 (Purple) Microphone (Input)
8 (Grey) GND