Avantco 178UBB48GT 사용자 설명서 - 페이지 7

{카테고리_이름} Avantco 178UBB48GT에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Avantco 178UBB48GT 11 페이지. Back bar refrigerator
Avantco 178UBB48GT에 대해서도 마찬가지입니다: 사용자 설명서 (7 페이지)

Avantco 178UBB48GT 사용자 설명서
Running a Manual Defrost Cycle
This unit is pre-programmed to run automatic defrost cycles at preset intervals. However, if you would like to
run a manual defrost cycle at any time, please follow the steps below:
1. Press the defrost button (snowflake symbol and down arrow) for approximately 3 seconds.
2. Repeat to stop the defrost cycle.
Defrost System:
Refrigerator coils are kept below the freezing point (32 degrees Fahrenheit). During compressor downtime,
the evaporator fan continues to circulate air through the evaporator coil. This air circulation raises the coil
temperature above the freezing point, melting any accumulated frost. Run-off water is drained into the
evaporator pan and evaporated. Automatic defrost timers automatically initiate at pre-set intervals and for a
pre-determined duration.

Safety / Warning

Please pay close attention to the safety notices in this section. Disregarding these notices may lead to seri-
ous injury and/or damage to the unit.
ATTENTION
To minimize shock and fire hazards, be sure not to overload outlet. Please designate one outlet for
your unit.
Do not use extension cords.
Do not put your hands under the unit while it is being moved.
When the unit is not in use for a long period of time, please unplug the unit from the outlet.
After unplugging the unit, wait at least 10 minutes before plugging it back in. Failure to do so could
cause damage to the compressor.
UNPLUG CORD
To minimize shock and fire hazards, please do not plug or unplug the cord with wet hands.
During maintenance and cleaning, please unplug the unit.
PROPER GROUNDING REQUIRED
To minimize shock and fire hazards, make sure that the unit is properly grounded.
WARNING
Do not attempt to remove or repair any component unless instructed by factory.
Make sure that the unit is not resting on or against the electrical cord and plug.
To minimize personal injury, do not hang on the doors.
Do not store any flammable and explosive gas or liquids inside the unit.
Do not attempt to alter or tamper with the electrical cord.
User Manual
Back Bar Refrigerators
www.AvantcoRefrigeration.com
7