ENGLISH
DESCRIPTION:
1. MAINS INPUT: equipped with original Neutrik PowerCON
®
PowerCon
extension cable here.
2. MAINS OUTPUT: used to daisy chain the power to several other projectors. Always pay attention to the
maximum load while adding projectors! Special Multi cables (PowerCON
optionally available: see our website!)
3. DMX IN: used to daisy chain the projector with other units that will be controlled by a DMX-controller. The
DMX-input is also used to update the firmware of the projector, see the upgrade instructions on our
website.
4. DMX OUT: used to daisy chain the projector with other units that will be controlled by a DMX-controller.
5. DISPLAY: shows the various menus and the selected functions:
6. MENU-button: used to browse the different menu options or to exit a menu option.
7. ENTER-button: used to select a menu option or confirm a setting.
8. ▲-button: used to go to the previous menu option or to increase a parameter value.
9. ▼-button: used to go to the next menu option or to decrease a parameter value.
10. SAFETY EYE: used to attach a safety cable when the unit is rigged, see paragraph "overhead rigging".
11. FROST FILTERS: 2 filters (10° and 45°) are included to make the very narrow 4° beam wider. Use the
metal ring to fix one of these filters in front of the 4° lens.
12. HANGING BRACKET: with a knob on both sides to fasten the unit in the desired position. you can use
the hole in the center of the bracket to fix a hook or truss clamp.

OVERHEAD RIGGING

Important: The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials should
be used, the installed device should be inspected regularly for safety.
 Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.
 Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed at least 50cm from surrounding walls.
 The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.
 Before rigging make sure that the installation area can hold a minimum point load of 10times the device's
weight.
 Always use a certified safety cable that can hold 12times the weight of the device when installing the unit.
This secondary safety attachment should be installed in a way that no part of the installation can drop
more than 20cm if the main attachment fails.
 The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!
 Don't cover any ventilation openings as this may result in overheating.
 The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.