Briteq BEAMSPOT1-TRIAC NW 운영 매뉴얼 - 페이지 5

{카테고리_이름} Briteq BEAMSPOT1-TRIAC NW에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Briteq BEAMSPOT1-TRIAC NW 8 페이지.

Briteq BEAMSPOT1-TRIAC NW 운영 매뉴얼
ENGLISH
DESCRIPTION:
1. MAINS INPUT: 1m power cord with standard CEE 7/7 mains plug.
2. MAINS FUSE: protects the unit in case of electrical problems, always use the prescribed fuse!
3. MANUAL DIMMER: used to dim the output manually.
4. FROST FILTERS: 2 filters (10° and 45°) are included to make the very narrow 4° beam wider. Use the
metal ring to fix one of these filters in front of the 4° lens.
5. HANGING BRACKET: with a knob on both sides to fasten the unit in the desired position. you can use
the hole in the center of the bracket to fix a hook or truss clamp.
6. SAFETY EYE: used to attach a safety cable when the unit is rigged, see paragraph "overhead rigging".

OVERHEAD RIGGING

Important: The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials should
be used, the installed device should be inspected regularly for safety.
 Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.
 Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed at least 50cm from surrounding walls.
 The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.
 Before rigging make sure that the installation area can hold a minimum point load of 10times the device's
weight.
 Always use a certified safety cable that can hold 12times the weight of the device when installing the unit.
This secondary safety attachment should be installed in a way that no part of the installation can drop
more than 20cm if the main attachment fails.
 The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!
 Don't cover any ventilation openings as this may result in overheating.
 The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.
BRITEQ
®
3/5
BEAMSPOT1-TRIAC NW (WW)
OPERATION MANUAL