Ganz ZN-RS4000AE series 하드웨어 매뉴얼 - 페이지 16

{카테고리_이름} Ganz ZN-RS4000AE series에 대한 하드웨어 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Ganz ZN-RS4000AE series 20 페이지. 1u 12ch rack for ganz encoder series

ZA-NVE12K Hardware Manual

4.3. Electrical characteristics

Output
Input
PROTECTION
FUNCTION
SAFETY &
EMC
(Note 5)
2010/2-1 E
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
PEAK LOAD(10sec.)
Note.4
RIPPLE & NOISE
(max.) Note.2
VOLTAGE ADJ.
RANGE
VOLTAGE
TOLERANCE Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT
(Typ.)
LEAKAGE CURRENT
OVER LOAD
OVER VOLTAGE
REMOTE ON/OFF
SAFETY STANDARDS
WITHSTAND
VOLTAGE
ISOLATION
RESISTANCE
EMI CONDUCTION &
RADIATION
HARMONIC
CURRENT
Table 3. Electrical specification of PSU
12V
6.2A
0 ~ 6.8A
74.4W
81.6W
80mVp-p
3 ~3.5V
3.00%
1.00%
3.00%
100ms, 35ms/230VAC 100ms,
35ms/115VAC at full load
60ms/230VAC 12ms/115VAC at full load
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
80%
1.9A/115VAC 1.1A/230VAC
COLD START 18A/115VAC
36A/230VAC
<1mA / 240VAC
115 ~ 150% rated output power
Protection type : Hiccup mode, recovers
automatically after fault condition is
removed
13.8 ~ 16.2V
Protection type : Hiccup mode, recovers
automatically after fault condition is
removed
RC+/RC- : 0 ~ 0.8V power on ; 4 ~ 10V
power of
UL60950-1, TUV EN60950-1 Approved
I/P-O/P:3KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M
Ohms/500VDC
Compliance to EN55011, EN55022
(CISPR22) Class B
Compliance to EN61000-3-2,-3
I/P-FG:1.5KVAC
16