Step 11: Attach 4 door hinges to Left and right door [Q and R] with 8 mounting screws [T] (2
screws for each hinge) as shown in Fig K. Attach left and right door [Q and R] to panel C and D
with 8 mounting screws [T] (2 screws for each hinge). See Fig. K. Attach door handles [Rs] to
left and right door with 2 door screws [Rt].
Step 12: Tighten all KD screws.
FirEPlAcE iNSErt iNStAllAtiON:
The fireplace insert can be installed after the mantel has been fully assembled.
wARNINg: MAke suRe THe fIRePLACe INseRT CONTROLs ARe IN THe Off
POsITION AND THe uNIT Is NOT PLuggeD IN.
Step 1: Carefully place the insert in the unit opening. The front of insert should be flush
with the front of the mantel. Carefully lift the insert into the mantel until the top
stopper is against the mantel.
Step 2: Attach 2 small brackets [M] at the top of insert with 2 KD screws. Attach the
L-mounting bracket to Base [B] panel with 2 short KD screws. See Fig. L.
Step 3: Move assembled unit to desired location. Unit should not be positioned in area
exposed to direct sunlight.
fRONT
Fig. K
Fig. N
BACk
OPErAtiON
After reading complete instructions, confirm all controls on the fireplace are in the oFF position.
Plug the fireplace into a 15AMP/120Volt outlet. If the cord does not reach, you may use an
extension cord rated for a minimum of 1875 WATTS. once the fireplace insert has been
properly connected to a grounded electrical outlet, it is ready to operate.
OPErAtiON BY tHE cONtrOl PANEl
The controls are located behind the grill below the front glass and can be accessed by pulling
the grill from the top, forward and down.
wARNINg: DO NOT TOuCH HOT suRfACe AT CeNTRe Of gRILL, HANDLe, LefT OR
RIgHT sIDe Of gRILL wHeN PuLLINg OuT.
O/I: Press this button for main power and flame effect. The indicator light will turn on.
750w: For low heat function - Press this switch while the o/I switch is in the on position for low
heat. The indicator light will turn on.
1500w: For high heat function - Press this switch while the o/I switch and the 750W switch
are in the on position for high heat. The indicator light will turn on.
TeMPeRATuRe CONTROL: To adjust the temperature to your individual requirements,
turn the temperature control dial to the right (clockwise) to increase the desired
temperature and to the left for lower temperature. This temperature control dial can only be
used while the o/I switch and 750W & 1500W switches are in the oN position. When the
heater reaches to the desired temperature, the heater and 750W/1500W indicator light will
off but the fan still keeps working with air flow. Adjust this knob to restart the heater.
DIMMeR CONTROL kNOB: Turn the dimmer dial clockwise or counter clockwise
to get the desired flame intensity. The dimmer switch can only be used when the o/I
switch is in the on position.
NOTe: When the o/I switch is turned oFF, the heater functions will stop even though the
switches may be in the oN position.