HIKVISION DeepinMind iDS-6700NXI-I/16S 빠른 시작 매뉴얼 - 페이지 10

{카테고리_이름} HIKVISION DeepinMind iDS-6700NXI-I/16S에 대한 빠른 시작 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. HIKVISION DeepinMind iDS-6700NXI-I/16S 16 페이지.

HIKVISION DeepinMind iDS-6700NXI-I/16S 빠른 시작 매뉴얼
DeepinMind Series NVS Quick Start Guide
iDS-6700 Deepi nMin d Ser ies NVS Quic k Star t Gui de

Chapter 3 Alarm Connections

3.1 Alarm Input Connections

The alarm input is an open/closed relay. To connect the alarm input to the device, use the
following diagram.
If the alarm input is not an open/close relay, please connect an external relay between the alarm
input and the device.
Figure 3-1 Alarm Input Wiring
To connect to an alarm output (AC or DC load), use the following diagram:
Figure 3-2 Alarm Output Wiring
For DC load, the jumpers can be used within the limit of 12V/1A safely.
To connect an AC load, jumpers should be left open (you must remove the jumper on the
motherboard in the NVS). Use an external relay for safety (as shown in the figure above).
There are 4 jumpers (JP6, JP9, JP10, and JP11) on the motherboard, each corresponding with one
alarm output. By default, jumpers are connected. To connect an AC load, jumpers should be
removed.
Example:
9