6. Using a seal/bearing punch (available at most automotive stores/harbor freight) firmly press the filter media to
ensure a tight packing in case pack was disrupted during the shipping process.
*** Important! Do not skip this step. Failure to pack will cause channeling which could result in poor filter

Installation

7.
a. For internal systems provided by the OEM attach the filter housing to the flange using the 2.5" tri-
clamp. The filter cartridge itself acts as the gasket. Tighten bolts to 10ft/lbs.
Place entire assembly back into column and follow reassembly procedures per manufacturers'
instructions.
b. For external systems running inline, assemble the base of the filter housing by installing the 2.5" -> 1.5"
reducer using a gasket and clamp. The base of the filter housing is the side closest to the screen plate.
Tighten bolts to 4ft/lbs.
performance and possible filter paper rupture. ****