Automatic Alarms
Automatic alarms are programmed to sound on your unit in the following instances:
Refrigerator Cabinet High/Low Temperature Alarm:
•
When the temperature reaches 8 degrees F above your
set point for 30 minutes
•
When the temperature reaches 1 degree F below your
set point for 30 minutes
•
If the refrigerator is above the temperature of 41
degrees F for 30 minutes
Freezers Cabinet High/Low Temperature Alarm:
•
When the temperature reaches 10.4F degrees, which is
18F degrees above your set point, for 30 minutes
•
When the temperature reaches -13.9F degrees, which is
6.3F degrees below your set point, for 30 minutes
Dirty Condenser Alarm
•
If the internal system determines your condenser to be
dirty an alarm will appear on the display
Running a Manual Defrost Cycle
This unit is pre-programmed to run automatic defrost cycles at preset intervals. However, if you
would like to run a manual defrost cycle at any time, please follow the steps below:
1. Press and hold the menu key
interface; (At this time, the display screen displays "--", then background
button lights up)
2. Click the
button in the upper left corner to start manual defrosting
3. Wait for about 7s, the digital display returns to the normal display interface
Defrost System
Refrigerator coils are kept below the freezing point (32° F). During compressor down-time, the
evaporator fan continues to circulate air through the evaporator coil. This air circulation raises the
coil temperature above the freezing point, melting any accumulated frost. Run-off water is drained
into the evaporator pan and evaporated. Freezer coils are defrosted electrically. Automatic defrost
timers automatically initiate at pre-set intervals and for a pre-determined duration.
User Manual
for 3s to enter the menu selection
- 7 -