ERASING TRANSMITTERS (Fig. 3)
Push simultanously SYNC and STOP of the transmitter until the motor makes a brief movement in both
directions. Only the transmitter used for this procedure has been deleted from motor memory
FIG. 3
RESET MOTOR MEMORY
OPTION 1 (Fig. 4) - Using an already programmed transmitter
Press and hold both SYNC and STOP buttons till the motor makes first a brief jog and, after a while, a
second long jog. Memory is now empty.
FIG. 4
OPTION 2 (Fig. 5) - Without an already programmed transmitter
1. Switch the motor power supply OFF. Then switch it ON.
2. Within 8 seconds, using any Gaposa transmitter, press and hold both SYNC and STOP buttons until the
motor makes a long jog. Memory is now empty.
FIG. 5
ON
OFF
ON
LIMIT SWITCH SETUP (Fig. 6)
ATTENTION: ALWAYS SET THE UP LIMIT SWITCH FIRST
1. Push LIMIT till the motor makes a brief movement in both direction
Note: during "programming mode" the operations are in "deadman control"
2. Press and hold the
3. Press the
STOP to set the UP limit position. The motor makes a brief jog.
4. Press and hold the
5. Press the
STOP to set the DOWN limit position. The motor makes a brief jog.
Note: accurate limit setting can be performed when UPWARD or DOWNWARD by pressing a second time LIMIT:
the motor then moves slowly in steps towards to the desired limit. Always press STOP button to set the limit
position.
www.AVOutlet.com
(Just for motors with electronic limit switch)
UP button and run the motor to the desired UP limit position.
DOWN button and run the motor to the desired DOWN limit position.