6. ADDING TRANSMITTERS

1
Press and hold the PROG-
TX button on the back of
transmitter ALREADY PAIRED
until the motor starts moving
7. CHECKING / CHANGING DIRECTION
Press UP or DOWN the motor should go UP or DOWN, otherwise to change the motor direction:
1
Press and hold the PROG-TX button on the
back of transmitter until the motor starts
moving

8. LIMIT SWITCH SETUP

1
Run the motor to an intermediate position
inbetween the two desired limits. The
motor needs to move in the direction
of the limit in order for the limit to be
properly set.
Press and hold the PROG-FC
button on the back of transmitter
until the motor makes a brief jog.
Note: during "programming
mode" the operations are in
"deadman control" (The UP and
DOWN buttons must be held
down inorder to move the motor)
Note: Accurate limit setting can be performed when UPWARD or DOWNWARD by pressing the PROG-FC button
a second time: the motor then moves slowly in steps towards to the desired limit. Always press STOP button
to set the limit position
6
2
Check the motor rotation
then release the PROG-TX
button (the motor stops)
2
Press STOP: The motor makes a brief jog. Direction of the
motor has been reversed.
IMPORTANT: change direction must be performed before
starting limit setting otherwise limits must be reset
ALWAYS SET THE UP LIMIT FIRST.
2
Press and hold the
UP button and run
the motor to the
desired UP limit
position
4
Press and hold the
DOWN button and
run the motor to the
desired DOWN limit
position.
3
Within 5 seconds, press the
corresponding button (UP if the
motor turns upwards or DOWN if
the motor turns downwards) on
the new transmitter that needs to
be programmed
3
Press STOP to set the
UP limit position. The
motor makes a brief jog
to confirm
5
Press STOP to set the
UP limit position. The
motor makes a brief
jog to confirm.