Avantco 178AU27FHC 사용자 설명서 - 페이지 9

{카테고리_이름} Avantco 178AU27FHC에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Avantco 178AU27FHC 10 페이지. Commercial refrigerators and freezers
Avantco 178AU27FHC에 대해서도 마찬가지입니다: 사용자 설명서 (9 페이지)

Avantco 178AU27FHC 사용자 설명서
A dusty condenser may lead to high energy consumption, less cooling effectiveness, and
compressor damage.
Condenser Coil Cleaning Instructions:
The condenser coil is located at the bottom behind the panel.
1. Disconnect the electrical power from the unit.
2. Remove the front cover and base cover with a screwdriver.
3. Using a soft brush and / or vacuum, remove the dirt, lint, etc. from the finned condenser coil in a
vertical direction.
4. Clean the condenser with a commercial condenser coil cleaner, available from any kitchen
equipment retailer. Ex. Nobel Chemical Tech Line
5. After cleaning, straighten any bent condenser fins with a fin comb.
6. When finished, be sure to reinstall the front cover and base cover.
7. Reconnect the electrical power to the unit.

Troubleshooting

Compressor Not Running
Fuse blown or circuit breaker tripped.
Power cord unplugged.
Thermostat set too high.
Cabinet in defrost cycle.
Condensing Units Run for Long Periods of Time
Excessive amount of warm product placed in
cabinet.
Prolonged door opening or door ajar.
Door gasket(s) not sealing properly.
Dirty condenser coil.
Evaporator coil iced over.
www.AvantcoRefrigeration.com
User Manual
Replace fuse or reset circuit breaker.
Plug in power cord.
Set thermostat to lower temperature.
Wait for defrost cycle to finish.
Allow adequate time for product to cool down.
Ensure doors are closed when not in use. Avoid
opening doors for long periods of time.
Ensure gaskets are snapped in completely. Remove
gasket and wash with soap and water. Check
condition of gasket and replace if necessary.
Clean the condenser coil.
Unplug unit and allow coil to defrost. Make sure
thermostat is not set too cold. Ensure that door
gasket(s) are sealing properly.
9