Avantco 178AWT27FHC 사용자 설명서 - 페이지 5

{카테고리_이름} Avantco 178AWT27FHC에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Avantco 178AWT27FHC 9 페이지. Commercial refrigerators and freezers
Avantco 178AWT27FHC에 대해서도 마찬가지입니다: 사용자 설명서 (10 페이지)

Avantco 178AWT27FHC 사용자 설명서
User Manual
Freezer Control

Loading Product

Before loading shelves, please be sure that all shelf clips are completely fastened in their correct
locations. It is important that all shelves rest completely level before stocking your cabinet with product.
In order to maintain correct air flow inside the unit, please be sure to leave two to four (2 to 4) inches
of space between the back wall and stored product. Blocking the evaporator fans will result in a
warmer cabinet temperature, and ultimately compressor failure.
Running a Manual Defrost Cycle
This unit is pre-programmed to run automatic defrost cycles at preset intervals. However, if you
would like to run a manual defrost cycle at any time, please follow the steps below:
Freezers: Press the defrost button ("def" and down arrow) for approximately 5 seconds. Repeat to
stop the defrost cycle.
Refrigerators: Press the defrost button (snowflake symbol and down arrow) for approximately 3
seconds. Repeat to stop the defrost cycle.

Defrost Systems

Refrigerator coils are kept below the freezing point (32° F). During compressor down-time, the
evaporator fan continues to circulate air through the evaporator coil. This air circulation raises the coil
temperature above the freezing point, melting any accumulated frost. Run-off water is drained into
the evaporator pan and evaporated. Freezer coils are defrosted electrically. Automatic defrost timers
automatically initiate at pre-set intervals and for a pre-determined duration.
Refrigerator Control
Prg
aux
mute
Set
def
- 5 -
set