3 EWS-102 Setup and Calibration Garan3.pdf 1 17/05/2016 14:17:13
EWS-102 CONTROL UNIT
To begin the load
calibration, press the
and
buttons together.
C
M
Y
CM
MY
CY
CMY
K
Rev 2.1 subject to alteration
Press the
button to enter the load calibration menu.
Load Calibration
After placing the known load within the elevator cabin, press the
When the dashes are displayed, sett he value oft he required load in kilograms. Use the
button to selectt he required digit (selected digitf lashes) and use the button to sett he
required digit value.
For example: Using a known load of 75Kg
x7
x5
To complete the action, press the
The instrumentt hen counts down from 10 to 1.
Upon completions, the screen will display CAL for approximately 10 seconds and then the
system will return to Operation Mode. The load has now been calibrated.
button.
CALIBRATION LOAD
button to proceed.
www.garan.co.uk