1. Introduction
The Direct-attach Fiber-Optic Shutter DA-SHUTTER is used for automatic shuttering of a
spectrometer.
2. Direct-attach Fiber-Optic Shutter DA-SHUTTER Operating Manual
2.1 General
I/O
connector
12V DC
connector
2.2 Technical Data
Description
Power requirement
Shutter frequency
Shutter delay
Dimensions shutter (DxH)
Dimensions control box (HxLxW)
Weight shutter
Weight control box
Material mechanical
Material optical
Fiber connection
* without COL-UV/VIS, I/O and DA-SHUTTER connectors
Revision: 2-00
© Avantes BV
Specification
12V DC (positive centre)/ 500 mA
Max. 5 Hz
15 ms
30 x 38 mm*
28 x 58 x 45 mm*
70 grams
60 grams
Black anodized aluminum
UV Fused silica
SMA-905 connector