KitchenAid KDRP707RSS01 설치 지침 매뉴얼 - 페이지 4

{카테고리_이름} KitchenAid KDRP707RSS01에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. KitchenAid KDRP707RSS01 16 페이지. 30" (76.2 cm) and 36" (91.4 cm) classic commercial-style dual fuel convection range with steam-assist
KitchenAid KDRP707RSS01에 대해서도 마찬가지입니다: 부품 목록 (10 페이지)

TipOverHazard
Achildor adultcantip therange andbekilled.
Connect antFtip bracket towallbehind range,
Reconnect theantFtip bracket, iftherange is moved.
Failure t ofollowthese instructions c anresult i ndeath or serious burns to children andadults.
INSTALLATION REQUIREMENTS
Backguard and attachment
screws (7).
Gather the required tools and parts before starting installation.
Read and follow the safety instructions
provided with any tools
listed here.
Tools needed
Tape measure
15/16" combination
wrench
Flat-blade screwdriver
Marker or pencil
Phillips screwdriver
Masking tape
Level
Pipe-joint compound
resistant to LP gas
Hand or electric drill
Channel lock pliers
Noncorrosive leak-detection
solution
Pipe wrench
Stud finder
Parts needed
A UL listed or CSA approved conduit connector
ULlisted
wire nuts
Parts supplied
Check that all parts are included.
Anti-tip bracket kit
(2.51" c m)"_ 11_
I_'Jv_4.4
crn)
B
A. Anti-tip bracket
B. #!0 x 2" Phillips head screws (2)
NOTE: The backguard included with the range is required if
installed with less than 1" (2.5 cm) clearance from a
combustible
rear wall.
Island trim and attachment
screws (3).
NOTE: The island trim included with the range may be used if
installed with 1" (2.5 cm) clearance from a combustible
rear
wall or with 0" (0 cm) clearance from a noncombustible
rear
wall.
LP conversion kit.
NOTE: The cooktop is manufactured
for use with Natural gas.
To convert to LP gas, see the gas conversion instructions
provided in the literature package.
Check local codes and consult gas supplier. Check existing gas
supply and electrical supply. See "Electrical Requirements"
and
"Gas Supply Requirements"
sections.
All electrical connections should be made by a licensed, qualified
electrical installer.
IMPORTANT: Observe all governing codes and ordinances.
Do
not obstruct flow of combustion
and ventilation air.
It is the installer's responsibility
to comply with installation
clearances specified on the model/serial rating plate. The
model/serial
rating plate is located on the vertical surface
below the control panel on the right.
It is recommended
that a 600 CFM range hood be installed
above the range.
Recessed installations must provide complete enclosure of
the sides and rear of the range.
To eliminate the risk of burns or fire by reaching over heated
surface units, cabinet storage space located above the
surface units should be avoided. If cabinet storage is to be
provided, the risk can be reduced by installing a range hood
that projects horizontally a minimum of 5" (12.7 cm) beyond
the bottom of the cabinets.
NOTE: Brackets must be securely attached to wall stud.
Thickness of finished wall may require longer screws to anchor
bracket to wall. Longer screws are available from your local
hardware store. See "Install Anti-Tip Bracket" section.
All openings in the wall or floor where range is to be installed
must be sealed.