Gardasoft Vision PP861 사용자 설명서 - 페이지 12

{카테고리_이름} Gardasoft Vision PP861에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Gardasoft Vision PP861 17 페이지. Led lighting controller

12
10

Serial Commands

10.1

Command Structure

The PP860 can be programmed via a serial communications link either from
within the user's custom code using MSCOMMS32 or using a Gardasoft
demonstration
program
(check
www.gardasoft.com ) . Alternatively a utility such as HyperTerminal running
on a PC can be used to program an individual unit.
The communications port should be set to 115Kbaud, no parity, 8 data bits, 1
stop bit.
The commands comprise a code of two upper case letters followed by the
parameters (if any) needed for the command. Spaces in the commands are
ignored. A carriage return character should be sent to terminate the command.
Time is defined in microseconds:
20
20us
1500
1.5ms
Current is in amps
0.2
0.2A
1.5
1.5A
20
20A
All responses from the PP860 are terminated with a '>' character to indicate
that the command is complete.
If a command is invalid, one of the following error codes from Appendix A
returned.
Commands take effect immediately they are issued. Because of this, if the
settings are being changed from high current Pulsed Output mode to a
Continuous Output mode, it is advisable to set the current values to 0
using the RC command before changing mode. This prevents overload
conditions occurring.
Any changes made using RS232 commands are not saved permanently
until the AW command has been issued.