TECHNICAL SPECIFICATIONS
DIMENSIONS
The units are delivered fully assembled, tested and packed on a timber base with shockproof edges and protected by heat-shrunk plastic film.
On reception and after unpacking, check the equipment for domage. For transport purposes, refer to the weight and dimensions give below.
A
B
A mm
B mm
160
1432
620
240
1953
620
290
1784
720
380
2134
720
GENERAL FEATURES
Output
Operating voltage
Total capacity
Primary circuit capacity
Central heating connections
Domestic hot water connections
Hot water tank exchange surface
Weight when empty
Domestic hot water max. pressure
Central heating max. pressure
Expansion tank
Max. T° setting
4
F
D
E
C mm
D mm
E mm
720
1282
290
720
1800
290
800
1627
300
800
1985
300
E-tech S 160
E-tech S 240
kW
14.4
Volt
230
L
161
L
55
Ø
1"
Ø
3/4"
m
2
1.26
kg
115
bar
10
bar
3
1 x 8 L
°C
85
G
C
F mm
G mm
H mm
43
265
405
43
265
405
92
265
435
92
265
435
E-tech S 290
E-tech S 290
single phase
14.4
14.4
230
230
242
295
68
97
1"
1"
3/4"
1"
1.87
2.0
155
202
10
10
3
3
1 x 8 L
2 x 8 L
85
85
K
K
H
I
J
I mm
J mm
K mm
310
127
180
310
127
180
360
94
135
360
94
135
E-tech S 380
E-tech S 380
tri phase
mono phase
28.8
14.4
3 x 400 + N
230
295
394
97
127
1"
1"
1"
1 1/2"
2.0
2.6
202
230
10
10
3
3
2 x 8 L
2 x 8 L
85
85
L
L mm
126
126
96
96
tri phase
28.8
3 x 400 + N
394
127
1"
1 1/2"
2.6
230
10
3
2 x 8 L
85