IPI ELECTRONIC SYSTEM OPERATING INSTRUCTIONS (BP7 SERIES)
ELECTRONIC CONTROL VALVE
The electronic control valve system includes the ability to switch
the pilot from a standing pilot mode to an intermittent pilot mode.
IPI Mode - In the Intermittent Pilot mode, when the unit
is turned ON, it will cause spark to the pilot, light the
pilot, then allow the burner to light. When the unit is
turned to OFF, both the burner and pilot will be OFF.
CPI Mode - In the Continuous Pilot mode, the pilot
remains ON continuously even when the burner is
turned OFF. During the heating season (or in power
outage periods), it is recommended that the pilot remain
in the CPI (standing pilot mode) to reduce cold start
issues, and/or conserve battery backup power during a
power outage.
NOTICE: A small toggle switch is located on the front of the
module tray that is used to switch from IPI (left) to the
CPI (right). See Figure 3.
NOTICE: The gas control has a manual HI/LO flame adjustment
knob (regulator) that allows you to increase or
decrease the height of the burner flame. See Figure
3. Rotate the HI/LO knob counterclockwise to "HI"
to increase the flame height, and clockwise to "LO"
to decrease the flame height.
OPTIONAL REMOTE CONTROLS
Optional remote controls are available for use with this fireplace.
Contact your dealer.
37620-0-1116
PILOT SELECTOR SWITCH
IPI - INTERMITANT PILOT (LEFT)
CPI - CONTINUOUS PILOT (RIGHT)
AA (4)
BATTERY
BACKUP
MANUAL
HI/LO
REGULATOR
Figure 3
MANUAL ON/OFF SWITCH
GAS VALVE
Page 5