Jandy Jandy Pro Series 설치 및 운영 매뉴얼 - 페이지 7

{카테고리_이름} Jandy Jandy Pro Series에 대한 설치 및 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Jandy Jandy Pro Series 20 페이지. Single element cartridge pool & spa cs filters
Jandy Jandy Pro Series에 대해서도 마찬가지입니다: 소유자 매뉴얼 (12 페이지), 설치 매뉴얼 (16 페이지), 소유자 매뉴얼 (20 페이지), 매뉴얼 (8 페이지), 빠른 시작 매뉴얼 (2 페이지), 설치 및 운영 매뉴얼 (20 페이지), 설치 지침 (2 페이지), 설치 및 운영 매뉴얼 (16 페이지), 설치 및 운영 매뉴얼 (16 페이지), 설치 및 운영 매뉴얼 (16 페이지)

Jandy Jandy Pro Series 설치 및 운영 매뉴얼
Jandy
FILTER
HEATER
CHECK VALVE
(Check Valve recommended
for systems installed with Erosion Feeders
or Aquapure salt chlorination systems)
SPA RETURN
Figure 2. Typical Piping Installation
NOTE When the pool equipment is located below the
pool surface a leak can result in large scale
water loss or fl ooding. Zodiac Pool Systems
LLC cannot be responsible for such water
loss, fl ooding or damage caused by either
occurrence.
3. Install the pump such that any disconnecting means
and/or junction boxes for power connection are
within sight of the pump and at least fi ve (5) feet
horizontally from the edge of the pool and/or spa.
4. Choose a location that will minimize turns in the
piping.
NOTE In Canada, the minimum distance maintained
from the edge of the pool and/or spa as noted
above must be 3 meters (10 feet), as required
by the Canadian Electrical Code (CEC, CSA
C22.1).
5. The pump must be placed on a solid foundation
that will not vibrate.
NOTE: To further reduce the possibility of vibration
noise, bolt the pump to the foundation, or place
it on a rubber mat.
6. The pump foundation must have adequate
drainage to prevent the motor from getting wet.
7. Protect the pump from the rain and sun.
Pro Series VS PlusHP Pumps
®
PUMP
a.
POOL
RETURN
|
Installation & Operation Manual
POOL/SPA
3 WAY VALVE
SKIMMER
MANUAL BY-PASS DETAIL:
USE WHEN FILTRATION RATE
EXCEEDS 125 GPM FOR ZODIAC
HEATERS. REFER TO THE MANUFAC-
TURER'S RECOMMENDATIONS IF
USING A DIFFERENT BRAND HEATER.
8. Proper ventilation is required for the pump to
operate normally. Motor generated heat must be
removed by adequate air fl ow.
9. Provide access for future service by leaving a
clear area around the pump. Allow plenty of space
above the pump to remove the lid and basket.
10. If the equipment is under cover, provide adequate
lighting.
3.1.2 Pipe Sizing
If pump is located within 50 feet (15 m) of the pool,
the recommended minimum pipe size for suction and
discharge is 2.5 inches (64 mm). For lengths greater
than 50 feet increase the pipe size according to "Table 1.
Pipe Sizing for Schedule 40 PVC".
3.1.3 Installation Recommendations
1. To help prevent diffi culty in priming, install the
suction pipe without high points (above inlet of
pump, or inverted "U"s, commonly referred to in
plumbing as "airlocks") that can trap air.
2. For installations of equipment up to 100 feet
(30 m) from the water, refer to "Table 1. Pipe
Sizing for Schedule 40 PVC", For installations
of equipment more than 100 feet (30 m) from
the water, the recommended pipe size must be
increased to the next size.
ENGLISH
SPA DRAIN
(Suction Outlet)
a.
MANUAL BYPASS VALVE
Page 7