KitchenAid KEBU107SSS00 설치 지침 매뉴얼 - 페이지 2
{카테고리_이름} KitchenAid KEBU107SSS00에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. KitchenAid KEBU107SSS00 20 페이지. 30" (76.2 cm) electricsingle and double built-in oven
KitchenAid KEBU107SSS00에 대해서도 마찬가지입니다: 부품 설명서 (7 페이지)
BUILT-IN OVEN SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow
instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
INSTALLATION REQUIREMENTS
Gather the required tools and parts before starting installation.
Read and follow the instructions
provided with any tools listed
here.
Tools needed
•
Adjustable wrench or %" wrench
•
Phillips screwdriver
•
Flat-blade screwdriver
•
Measuring tape
•
Hand or electric drill (for wall cabinet installations)
•
1" (25 mm) drill bit (for wall cabinet installations)
•
Level
•
Copper tubing cutter
Parts supplied (1 box, 3 plastic bags)
•
One - 3/8"stem to 1/4"quick connect
•
Two - 3/8"elbow to 1/4"quick connects
•
Water filter
•
#10-16 x 3/8"screw and 1 mounting ring (to mount water filter)
•
#8-14 x 1" screws - single oven (2), double oven (4)
•
Bottom vent (supplied on some models)
•
#8-18 x 3/8"screws - bottom vent (supplied on some models)
Parts needed
•
UL listed or CSA approved conduit connector
•
UL listed wire connectors
•
Tubing staples/retainers
•
1A" O.D. copper tubing (to make water connection)
NOTE: Due to temperatures
around oven, copper tubing is
required.
•
Water connection device (to connect 1A"O.D. copper tubing
to water source). Check local codes for type of connection
required.
•
1A"to 1/4"water supply union (between copper tubing from the
filter and copper tubing attached to oven)
Check local codes. Check existing electrical supply. See
"Electrical Requirements."
It is recommended
that all electrical connections
be made by a
licensed, qualified electrical installer.
IMPORTANT: Observe all governing codes and ordinances.
•
Cabinet opening dimensions that are shown must be used.
Given dimensions
provide minimum clearance with oven.
•
Recessed installation area must provide complete enclosure
around the recessed portion of the oven.
•
Grounded electrical supply is required. See "Electrical
Requirements"
section.
Electrical supply junction box should be located 3" (7.6 cm)
maximum below the support surface when the oven is
installed in a wall cabinet. A 1" (2.5 cm) minimum diameter
hole should have been drilled in the right rear or left rear
corner of the support surface to route the oven conduit
through to the junction box.
NOTE: For undercounter
installation, it is recommended
that
the junction box be located in the adjacent right or left
cabinet. If you are installing the junction box on rear wall
behind oven, the junction box must be recessed and located
in the upper or lower right or left corner of the cabinet;
otherwise, the oven will not fit into the cabinet opening.