Removing Guaranteed Power from a Port
To remove guaranteed power from a port:
• In the Port column, select the port or ports from which the guaranteed power needs to
be removed.
• Select Not Guaranteed from the drop-down box.
• Click Apply.
Disabling Power on a Port
To disable power on a port:
• In the Port column, select the port or ports for which the power is to be disabled.
• Click Disable.
Enabling Power on a Port
To enable power on a port:
• In the Port column, select the port or ports for which the power is to be enabled.
• Click Enable.
For example, Figure 8 shows the power status for ports 1-3 after disabling inline power.
Note the power state for ports 1-3 is changed to Disabled.
SZ; Reviewed:
WCH 3/19/2004
Figure 8: Disable Inline Power Configuration