KitchenAid KEHU309SSS00 설치 지침 매뉴얼 - 페이지 5

{카테고리_이름} KitchenAid KEHU309SSS00에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. KitchenAid KEHU309SSS00 8 페이지. 30" (76.2 cm) electric built-in microwave/oven combination

Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge solid copper wire.
Electrically ground oven.
Failure to follow these instructions can result in death,
fire, or electrical shock.
This oven is manufactured
with a neutral (white) power supply
wire and a cabinet-connected
green (or bare) ground wire twisted
together.
1. Disconnect
power.
2. Feed the flexible conduit from the oven through the opening
in the cabinet.
3. Remove junction box cover, if it is present.
4. Install a UL listed or CSA approved conduit connector to the
junction
box.
A. UL listed or CSA approved conduit connector
5. Route the flexible conduit from the oven to the junction box
through a UL listed or CSA approved conduit connector.
6. Tighten screws on conduit connector.
7. See "Electrical Connection
Options Chart" to complete
installation for your type of electrical connection.
Electrical
Connection
Options Chart
4-Wire Cable from Home Power Supply
IMPORTANT: Use the 4-wire cable from home power supply in
the U.S. where local codes do not allow grounding through
neutral, New Branch circuit installations (1996 NEC), mobile
homes and recreational vehicles, new construction
and in
Canada.
A
H
A. Cable from home power supply
B. Black wires
C. Red wires
D. 4-wire flexible conduit from
oven
E. Junction box
F. White wires
G. UL listed wire connectors
H. Green (or bare) ground wires
I. UL listed or CSA approved
conduit connector
1. Connect the 2 black wires (B) together using a UL listed wire
connector.
2. Connect the 2 red wires (C) together using a UL listed wire
connector.
3. Untwist white wire from green (or bare) ground wire coming
from the oven.
4. Connect the 2 white wires (F) together using a UL listed wire
connector.
5. Connect the green (or bare) ground wire (H) from the oven
cable to the green (or bare) ground wire (in the junction box)
using a UL listed wire connector.
6. Install junction box cover.
3-Wire Cable from Home Power Supply
IMPORTANT: Use the 3-wire cable from home power supply
If your home has:
Go to section:
where local codes permit a 3-wire connection.
4-wire
4-wire Cable from Home
Power Supply
1/2"
3-wire
3-wire Cable from Home
Power Supply
1/2"
)
A
B
D
E
G
A. Cable from home power supply
B. Junction box
C. Black wires
D. White wires
E. Green (or bare) ground wire
(from oven)
E 4-wire flexible conduit from
oven
G.Red wires
H. UL listed wire connectors
L UL listed or CSA approved