Jandy Pro Series K-2000 설치 및 운영 매뉴얼 - 페이지 19
{카테고리_이름} Jandy Pro Series K-2000에 대한 설치 및 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Jandy Pro Series K-2000 20 페이지. Electronic water leveler
Jandy Pro Series Levolor
II Electronic Water Leveler
®
Models K-2000
5.4
Fill Valve Will Not Turn ON
Is sensor light on?
YES
Is fill light on?
YES
What color
is light?
Red
24 Hour Lockout is in Effect.
- Check time to refill.
- Check valve operation.
- Check water supply.
- Check strainer.
|
Fill Valve Will Not Turn ON
YES
Is power light on?
NO
Are long sensor
probes in water?
Disconnect red and black
sensor wires from
control box.
Does sensor
light turn on?
NO
PCB is bad.
Green
Is there 24VAC
at blue wires
in control box?
Is there 24VAC
at valve?
Installation and Operation Manual
Check power to box.
- Circuit breaker
NO
- Line voltage
- Wire connections to box
- Transformer voltage wiring
YES
System is normal. Fill will not
NO
YES
Does fill light turn
on in 20 seconds?
NO
NO
YES
NO
Cable to valve is bad.
YES
Voltage is delivered to valve.
- If gate is closed, open it.
- If solenoid port is dirty, clean it.
- If solenoid is not working, replace it.
- If valve is clogged, clean it.
- If diaphragm is stuck, clean it.
- If diaphragm is bad, replace it.
ENGLISH
turn on when water is full.
YES
NO
Page 19