Gardena 19080 운영자 매뉴얼 - 페이지 4

{카테고리_이름} Gardena 19080에 대한 운영자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Gardena 19080 9 페이지. Smart automatic home & garden pump
Gardena 19080에 대해서도 마찬가지입니다: 사용 설명서 (18 페이지)

Gardena 19080 운영자 매뉴얼
v For sandy water, you should additionally use the GARDENA Pump
Preliminary Filter, art. 1730 (mesh size 0.1 mm).
The temperature of the pumped liquid must be between 2 °C to 35 °C.
Only stow the product in temperatures between 2 °C to 70 °C.

2. INSTALLATION

DANGER! Electric shock!
Risk of injury due to electric current.
v Disconnect the product from the mains before you install the
product.
Installation location [ Fig. I1 ]:
The pump must be installed in a location with sufficient venti­
lation in the area of the ventilation slots. It must be at a distance
of at least 5 cm from the walls. No dirt contamination (e. g. sand
or soil) may be sucked in through the ventilation slots.
Set up the pump so that it is prevented from slipping and that an appro-
priately large collecting vessel for draining the pump or the system can be
placed under the drain screw
(1)
.
Install the pump at a safe distance (min. 2 m) from the pumping medium.
If possible, install the pump higher than the surface of the water to be
pumped. If this is not possible, install a vacuum-resistant shut-off device
between the pump and the suction hose to allow the integrated filter to
be cleaned.
If the system is permanently installed, appropriate shut-off devices must
be installed on the input and output sides. Important for maintenance and
cleaning work on the pump or for shutdown, for example.
Connections:
CAUTION!
The GARDENA connection pieces on the intake and deli­
very sides may only be tightened by hand. Check whether the
seal ring is present and undamaged before screwing the suction
hose onto the suction inlet. When using metal connections,
damage could occur on the connection thread due to inapprop­
riate assembly. Therefore, screw on the connection fittings
with the upmost care. Use sealing tape only for sealing metallic
connection fittings.
Suction side:
Do not use modular water hose components on the suction side!
A vacuum-tight suction hose must be used e.g.:
– GARDENA Suction Hose Art. 1411 / 1418
– GARDENA Bore Hole Suction Hose Art. 1729
– GARDENA Suction Hose sold by the metre with
GARDENA Hose Clamp Art. 7192 / 7191.
If very fine dirt is present, we recommend the use of a GARDENA pump
preliminary filter Art. 1730 / 1731 in addition to the integrated filter.
To reduce the pump repriming time, we recommend to use a suction
hose with backflow preventer, which prevents the suction hose emptying
automatically when the pump is switched off.
Important for fixed installation:
For greater suction heads, use a suction hose with a small diameter (3/4").
Pressure side:
A pressure-resistant hose must be used on the pressure side, e. g.:
– GARDENA Garden Hose (3/4") Art. 18113 with
GARDENA Connection Set Art. 1752.
Important for fixed installation:
If the product is permanently installed in an enclosed space, only flexible
hoses (e.g. reinforced hoses) may be used for connecting the service
water supply, rather than rigid piping. Flexible hoses will reduce the
noise level and prevent damage caused by pressure surges. Install fixed
pipes at an upward gradient on the first 2 m only. To avoid damage to
the thread, ensure careful and accurate installation when using metal
connections.
To connect the suction hose [ Fig. I2 ]:
1. Screw the suction hose fitting
it by hand.
(3)
(4)
onto the suction inlet
and tighten
2. Slide the suction hose
(2)
onto the suction hose fitting
it e.g. with a GARDENA Hose Clamp Art. 7192 / 7191.
3. For suction head exceeding 4 m secure the suction hose
(e. g. by fastening it to a wooden post).
The pump and the suction hose are relieved from the weight of the
water.
To connect the pressure hose [ Fig. I3 ]:
The pressure hose can be connected either to the delivery side
33.3 mm (G1)-thread of the 120° swivelling connection
of the horizontal connection
(8)
.
1. Screw the tap connector
(7)
onto the pressure outlet
it by hand.
2. Connect the pressure hose with hose connector
connector
(7)
.

3. OPERATION

Operation with the GARDENA smart system App:
You can use the GARDENA smart system app to control all smart
system products from anywhere at any time. You can download the free
GARDENA smart system app from the Apple App Store or from the
Google Play Store.
In order to include, a GARDENA smart Gateway with internet connec-
tivity is needed. All GARDENA smart products are integrated via the app.
Follow the instructions inside the App.
Settings / Display via the app:
– Language
– Current flow
– Current pressure
– Standby
– Turn on pressure
– Total volume counter
– Frost Warning
– Leakage warning
ON (60 min)
ON (2 min)
OFF
– Errors
LED displays of the pump [ Fig. O1 ]:
(L1)
Watering LED / Error LED
• Green:
Water flows
• Off:
Standby (when
• Red flashing:
Error (see 6. TROUBLESHOOTING)
(L2)
Connection­LED
• Green flashing:
Wait for connection
• Green – orange – red: Signal quality
• Red flashing:
Inclusion not done
(L3)
Power­LED
• Green:
Power on
• Off:
Power off
Reset Button
The smart Automatic Home & Garden Pump will be reset to the factory
settings.
v Push the Reset button for a short time.
New connection.
– or –
v Push and hold down the Reset button for at least 5 seconds.
Cancels the existing connection and allows a new connection to be
established, e. g. different Gateway.
To start the smart Automatic Home & Garden Pump [ Fig. O2 / O3 ]:
DANGER! Electric shock!
Risk of injury due to electric current.
v Disconnect the product from the mains before you fill the
pump.
NOTE: The specified maximum self­priming level (see 7. TECHNI­
CAL DATA) is reached only when the pump is full and the pressu­
re hose is held up high directly upstream of the pressure output
during the first self­priming phase. This ensures that the pumped
medium cannot leak from the pressure hose. When using a full
suction hose with a check valve, it is not necessary to hold up the
pressure hose.
(3)
and secure
(5)
and / or
(5)
/
(8)
and tighten
(6)
onto the tap
(L3)
illuminates)
5