Gardena 6000/5 inox automatic 사용 설명서 - 페이지 10

{카테고리_이름} Gardena 6000/5 inox automatic에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Gardena 6000/5 inox automatic 17 페이지. Deep well pump
Gardena 6000/5 inox automatic에 대해서도 마찬가지입니다: 사용 설명서 (9 페이지), 사용 설명서 (9 페이지), 사용 설명서 (9 페이지), 운영자 매뉴얼 (9 페이지), 사용 설명서 (9 페이지), 사용 설명서 (10 페이지)

Gardena 6000/5 inox automatic 사용 설명서
22
The pump has switched off.
Possible cause
Rotary switch of non-return
valve is set to START.
Non-return valve of the
manometric switch is blocked.
Seal failed on the output side
(leak).
Deposits of dirt on the impeller
of the dry-running safety
device.
Throughput was < 140 l/h for
several minutes.
Note: Even a small leak (loss of just a few ml) can cause the
pressure to drop below the pressure needed for switching
on the pump. The cause is often small leaks in taps or WC-
cisterns.
Pump ON
Shortage of water during operation. The pump tries to draw in
flashes
water twice (4 min. pumping time with 1 minute interval).
The pump is in the wait position before starting new attempts at
suction after 1 min / 1 h / 5 h / 24 h.
The pump tries to draw in water 3 times (4 minutes pumping time
Pump ON
in each case after 1 h / 5 h / 24 h interval).
flashes
After 5 suction attempts, the pump switches off.
Possible cause
Leak on the suction side.
Suction hose is no longer in the
water.
Water reservoir (e.g. under-
ground storage tanks) empty.
Suction filter or backflow
preventer blocked.
After rectifying the faults ERROR 02, ERROR 03, ERROR 04, ERROR 07,
ERROR 09 the pump can only be restarted by pressing the reset
key.
The pump has switched on and off frequently although no water
has been drawn off.
Possible cause
Not watertight on the delivery
side (leak).
Remedy
➜ Turn rotary switch to RUN.
➜ Clean non-return valve
(see 7. Maintenance).
➜ Check outlet and all hose
and accessories connected
to it for leaks.
➜ Contact GARDENA Service.
➜ Increase throughput.
Remedy
➜ Check all the suction
connections.
➜ Submerge end of suction
hose fully in the water.
➜ Check the water level is
high enough.
➜ Clean filter or backflow
preventer.
Remedy
➜ Check delivery pipeline and
valves/ taps connected to it
for leaks.