Problem
Pump is running but the delivery
drops suddenly
Pump does not start
Pump stops during operation
Error-LED
(Wp)
on the control panel
flashes red [ Fig. O4 ]
Error-LED
(Wp)
on the control panel
illuminates red [ Fig. O4 ]
Error-LED
¥
on the battery flashes
[ Fig. O3 ]
¥
Error-LED
on the battery
illuminates [ Fig.O3 ]
(Lc)
Charging control lamp
charger does not illuminate [ Fig. T1 ]
Charging control lamp
(Lc)
charger flashes red [ Fig. T1 ]
NOTE: For any other malfunctions please contact the GARDENA service department.
Repairs must only be done by GARDENA service departments or specialist dealers approved
by GARDENA.

7. TECHNICAL DATA

Battery Pump
Max. delivery capacity
Max. pressure
Max. delivery head
Max. submersion depth
Max. media temperature
Min. water depth for operation
with foot / without foot (approx.)
Residual water level with foot /
without foot (approx.)
Weight (without battery)
Possible Cause
Foot / Filter is clogged.
Battery is not put completely into
the battery holder.
Battery is empty.
Battery is empty.
Dry-run protection.
Battery unit is overheated.
Engine is blocked.
Battery overload.
Under voltage.
Battery temperature is out of range.
Battery error / battery defective.
on the
Battery charger or charging cable
are not connected correctly.
on the
Battery temperature is out of range.
Unit
Value (Art. 1748)
l/h
2000
bar
2.0
m
20
m
1.8
°C
35
mm
50 / 25
mm
25 / 5
kg
1.8
Remedy
v Clean the foot / filter.
v Put the battery completely into
the battery holder until it audibly
engages.
v Charge the battery.
v Charge the battery.
v Submerge the pump deeper.
If necessary, switch the pump on
and off several times (venting).
v Let the battery unit cool down and
start the pump again.
v Contact the GARDENA Service.
v Let the battery unit cool down and
start the pump again.
v Charge the battery.
v Use the battery in surroundings
where temperatures are between
0 °C and 40 °C.
v Contact the GARDENA Service.
v Connect the battery charger and
charging cable correctly.
v Use the battery in surroundings
where temperatures are between
0 °C and 40 °C.
Value (Art. 1749)
2000
2.0
20
1.8
35
50 / 25
25 / 5
2.2
17