Gardena WP 900 사용 설명서 - 페이지 4

{카테고리_이름} Gardena WP 900에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Gardena WP 900 7 페이지. Fountain pump

Gardena WP 900 사용 설명서
Remote control
Example for application:
For operating water jets from the comfort of your patio or
your living room.
Products:
GARDENA Remote Control Set
GARDENA Remote Control Socket
Pond aeration
Example for application:
To aerate the pond.
Product :
GARDENA Pond Aerator
Filling the filter tank
Zeolith fulfils the following functions:
with zeolith
Filters the water (
.
Bonds with excessive nutrients and causes their decomposition
.
by bacteria (
Helps to keep the pond clean and maintain the biological
.
balance.
Provides stability for the pump.
.
GARDENA Zeolith, 1 l
GARDENA Zeolith, 5 l
Note :
To ensure the zeolith functions correctly, we recommend you
replace or clean it every 6 months (e.g. in salt water).
Information
Always unplug the pump first before working on it.
.
Before assembling system extensions first unscrew the pre-
.
assembled cascade and if necessary also the telescopic tube
of the pump and then screw one of the water jets on again
(
the ball-and-socket joint ensures that the water jet is
vertical).
Follow the Safety and Assembly Information attached to the
.
operating instructions.

Operation

Installing the pump
1. Remove the pump from the filter basket and screw the regulator
supplied onto the second opening of the pump up to the limit
stop (
replace the pump in the filter basket.
2. Put the pump on a stable base to ensure that the upper edge
of the filter tank is completely immersed in water.
Pay attention to
Please note the maximum submersion depth (see "Technical Data").
minimum water depth
12
Art. No. 7874
Art. No. 7875
Art. No. 7936
protection for the pump).
Ion exchange and the bonding of e.g. nitrate).
Art. No. 7914
Art. No. 7915
max. delivery capacity on the vertical outlet). Then
Starting the pump
Connect the power cable to a 230 V AC socket.
Caution! Pump will start running immediately!
A
Avoid dry operation
Avoid dry operation of the pump as dry running will produce
undesirable heat and destroy the pump.
Horizontal or
Loosen the regulator by turning it anti-clockwise until you
.
second outlet
achieve the desired water flow from the vertical pipe of the
fountain / water feature. The narrow, light grey ring makes it
easy to screw on another drawing point (e. g. for a stream).
You may connect other terminals to the second outlet.
.
For example, a separately installed water jet may be operated
via the GARDENA Fountain / Light Bracket, Art. No. 7886.
If necessary fix the light jet base with two screws.
Information:
This significantly reduces the volume of the vertical water jet.
If the max. delivery capacity of the second outlet is to be used
.
then the vertical outlet should be closed with the end cap sup-
plied.
Example:
.
Hose pipe connection with the GARDENA light jet base
We recommend the use of a 3 /4" (19 mm) GARDENA pond
hose pipe, Art. No. 7895, connected to with the GARDENA
"Profi" Maxi-Flow-System with Tap Connector (Art. No. 2801
and 2802) and the GARDENA "Profi" Maxi-Flow-System Hose
connectors (Art. No. 2817).

Care instructions

Cleaning the filter tank
Filter tank and pump should be free from dirt particles!
How to clean :
Disconnect the plug!
.
Remove the pump from the water.
.
If necessary remove the gravel.
.
Clean the pump and the filter using a water jet.
.
If there are deposits of dirt inside the pump then dismantle the
.
casing (
fittings with water.
Information: Do not use any hard objects or strong detergents!
Blocked feed impeller
If the feed impeller becomes blocked, the pump and the filter
should be cleaned (see above).
see „Dismantling") and carefully clean the interior
13