KitchenAid KWCU205HBT1 설치 지침 및 사용 및 관리 설명서 - 페이지 4

{카테고리_이름} KitchenAid KWCU205HBT1에 대한 설치 지침 및 사용 및 관리 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. KitchenAid KWCU205HBT1 13 페이지. 30"/36"/48" wall-mount canopy range hood
KitchenAid KWCU205HBT1에 대해서도 마찬가지입니다: 부품 목록 (4 페이지)

KitchenAid KWCU205HBT1 설치 지침 및 사용 및 관리 설명서
Venting methods
This canopy range hood is factory set for
venting through the roof or wall. For non-
vented (recirculating)installations,
see
"Non-Vented (Recirculating) Kits" on
back page.
Vent system needed for installation is not
included. 3-1/4" x 10" (8.3 cmx 25 cm)
rectangular, 7" (17.8cm) round, 8"
(20.3 cm) round or 9" (22.9 cm) round
vent may be used.The hood exhaust
opening is 3-1/4" x 10" (8.3 cmx 25 cm).
Vent system can terminate either through
the roof or wall. To vent through a wall,
a 90° elbow is needed.
The vent system length should not
exceed the lengths shown in the chart
below,
Vent size
Maximum length
3-1/4" x 10"
35 ft. (10.7 m)
(8.3 cmx 25 cm)
7" (17.8cm) round
40 ft. (12.2 m)
8" (20.3 cm) round
50 ft. (15.2 m)
9" (22.9 cm) round
60 ft. (18.3 m)
Vertical
roof venting
roof cap
3-1/4" x 10"
_'_
(8.3cmx 25 cm) /
]
L
TM
through
the roof
_
_:_..'_
i
Horizontal
wall venting
3-1/4-" x 10"
F
I
Calculating the vent system length
To calculate the length of the system
you need, add the equivalent feet for
each vent piece used in the system,
Vent Piece
45° elbow
90° elbow
90° flat elbow
transition to round
wall cap
3-1/4" x 10" (8.3 cm x 25 cm}
Rectangular
7.0feet
(2.1 m)
5.0 feet
(1.5 m)
12.0 feet
(3.7 m)
5.0 feet
(1.5 m)
0.0 feet
(0.0 m)
7" (17.8cm), 8" (20.3 cm}
or 9" (22.9 cm} Round
2.5 feet
(0.8 cm)
5.0 feet
(1.5 m)
3-1/4" x 10" (8.3 cmx
25 cm)
vent system
3-1/4"
x 10"
wail
(8,3 cm x 25 crn)
elbow
cap
Maximum length
= 35 ft. (10.7 m)
1-90
° elbow
= 5ft.
(1.5m)
8 ft. (2.4 m) straight
= 8 ft. (2.4 m)
1 -wallcap
= Oft.
(Ore)
Length of 3-1/4" x 10"
(8.3 cmx 25 cm)
system
= 13 ft.
(4 m)
Note: Flexible vent is Not
recommended.
If it is used, each foot of flexible vent
used is equivalent to two feet
(61 cm) of straight metal vent when
calculating the vent system length,
(Example: A flexible elbow equals two
standard elbows,)