Vent system can terminate either through the roof or wall. To vent
o
through the wall, a 90
elbow is needed.
Roof Venting
A
B
A. Roof cap
B. 10" (25.4 cm)
round vent
Typical In-line Blower Motor System Venting Installations
C
D
B
A
A
A. 10" (25.4 cm) round vent
B. Mount on top of ceiling joists.
C. Roof caps
D. Plywood (optional on some installations)
E. Mount on underside of roof rafters.
F. Mount from cross-members tied to trusses.
G. Duct horizontal; mount to cross-members
tied to trusses.
H. Wall cap
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Wall Venting
B
A
A. Wall cap
B. 10" (25.4 cm)
round vent
E
D
F
G
H
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet
(meters) for each vent piece used in the system.
Vent Piece
45° elbow
90° elbow
The maximum equivalent vent lengths are:
10" (25.4 cm) round vent - 60 ft (18.3 m)
Example vent system
90 elbow
2 ft
(0.6 m)
A
The following example falls within the maximum recommended vent
length.
A
1 - 90° elbow
1 - wall cap
8 ft (2.4 m) straight
Length of system
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Equivalent Length
2.5 ft
(0.8 m)
5.0 ft
(1.5 m)
Wall cap
6 ft (1.8 m)
= 5.0 ft (1.5 m)
= 0.0 ft (0.0 m)
= 8.0 ft (2.4 m)
= 13.0 ft (3.9 m)