Fault
No irrigation
Irrigation through incorrect
outlet (e.g. incorrect match-
up of programmes and
outlets)
Water Distributor does
not switch further
Only if Art. 1892
is not used
In the event of other faults please contact GARDENA Service.
Repairs should only be carried out by GARDENA service centres or dealers
A
authorised by GARDENA.
Possible cause
Close tap.
Outlets 1 and 2 are closed
with end caps.
Active outlets (flow lever on
On) are closed with end cap.
Flow lever for outlets in
use is not on On or not on
Off for outlets (with end cap)
not in use.
Programmes not correctly
matched up with outlets
(see viewing window).
After deactivation of the
programmes
(Bad Weather Function).
Dial disc pressed during
operating irrigation.
Pressure fluctuations in
Pressure Tank Unit.
Pressure is under 1 bar.
Water Distributor is dirtied.
Active outlet is closed
with end cap.
Irrigation days not identical
with all programmes.
No 5 min. pause between
programmes.
Remedy
v Open tap.
v Connect devices to
outlets 1 and 2.
v Connect devices to active
outlets.
v Put flow lever on On for
outlets in use and on Off
for outlets not in use.
v Check programme match-up.
v Using the dial disc, match
the active outlet (see viewing
window) to the desired
programme.
v Do not press the dial disc
during operation.
v Do not use a Pressure
Tank Unit.
v Clean filter, use Tap Con-
nector Art. 2801 / 2817 with
³⁄₄ " hoses on the inlet side,
reduce water consumption
on the dispensing device.
v Rinse Water Distributor.
Unscrew end cap.
v Water distributor
switches further.
v Set irrigation days to
be identical with all
programmes.
v Set a 5 min. pause between
the programmes.
15