6. TROUBLESHOOTING

DANGER! Risk of injury!
Cut injury when the product starts acciden-
tally.
v Slide the protective cover
before you troubleshoot the product [ Fig. T1 ].
To change the grass shear blade [ Fig. T2 ]:
Only an original GARDENA grass shear blade is
allowed to be used. A new blade can be ordered by
the GARDENA Service.
9
1. Push the button
and slide the lid
(2)
2. Remove the blade
.
3. If necessary clean the transmission chamber and lubri-
cate the excentric drive
(Vaseline).
4. Turn the excentric drive
5. Pull the crank
w
on the back side of the blade
middle.
(2)
6. Place the new blade
q
that the excentric drive
0
7. Slide the lid
upwards until it makes a click.
Problem
The jack flashes red
while charging
Runtime too low
Product does not cut cleanly
NOTE: For any other malfunctions please contact the GARDENA service department.
Repairs must only be done by GARDENA service departments or specialist dealers approved
by GARDENA.

7. TECHNICAL DATA

For Grass Shear / Shrub Shear
Battery capacity
Battery charging time
(80 % / 100 %)
Battery charger
Mains voltage
Mains frequency
Rated output current
Max. output voltage
Width of blade
Length of blade
(1)
(2)
over the blade
0
downwards.
q
with some acid-free grease
q
downwards.
(2)
in the
on the motor unit in such a way
w
is inserted in the crank
Possible Cause
Allowed battery temperature
was exceeded.
Blade soiled.
Blade blunt or damaged.
Unit
Value (grass shear)
Ah
2.15
h
3.5 / 4.5
V
100 – 240
Hz
50 – 60
mA
500
V (DC)
5.5
cm
8
cm
To change the shrub shear blade [ Fig. T3 ]:
Only an original GARDENA shrub shear blade is
allowed to be used. A new blade can be ordered by
the GARDENA Service.
1. Push the button
2. Remove the blade
3. If necessary clean the transmission chamber and lubri-
cate the excentric drive
(Vaseline).
4. Turn the excentric drive
w
5. Pull the crank
wards.
6. Slide the ring
e
7. Place the new blade
that the excentric drive
crank
w
.
0
8. Slide the lid
upwards until it makes a click.
.
9
0
and slide the lid
downwards.
(2)
.
q
with some acid-free grease
q
downwards.
on the back side of the blade
in the middle of the crank
w
(2)
on the motor unit in such a way
q
is inserted in the ring
Remedy
v Let the battery cool down.
Restart the charging.
v Clean and lubricate scissor blade in
accordance with the maintenance
instructions.
v Change the blade
(see To change the blade).
Value (shrub shear)
2.15
3.5 / 4.5
100 – 240
50 – 60
500
5.5
12
(2)
down-
.
e
of the