Avaya EA401 설치 및 운영 매뉴얼 - 페이지 10

{카테고리_이름} Avaya EA401에 대한 설치 및 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Avaya EA401 20 페이지. Avaya explosive atmosphere telephone installation & operation manual

Avaya Inc.

Replacement Of EA10H Telephone Handset Assembly

Note: The handset cord is a 3.0 m (10 ft) long coiled cable designed specifically
for use with the EA401 telephone. If damaged, the assembly may be replaced in
the field. Only an EA10H handset assembly may be connected to the EA401
Explosive Atmosphere telephone.
Completely unscrew the upper knurled collar.
Pull the old plug straight down.
Inspect the inside of the socket and the threads for dirt or damage; clean as
necessary.
For safe installation, the new handset MUST be placed firmly in the cradle
PRIOR to engaging the plug in socket.
Bring the new plug up to the socket and rotate the plug until the slot in the
shell lines up with the key in the socket. Insert plug into socket.
Screw the upper knurled collar onto the socket. Hand tighten only, Do Not
use a wrench.
Call back and forth to another set to check functionality.
Hang up firmly between each call.
NOTE: If the handset is being replaced because of an apparent telephone
malfunction, and the replacement fails to restore normal operations, contact
the manufacturer to arrange return of the unit for repair.
EA401: EXPLOSIVE
ATMOSPHERE TELEPHONE
HANDSET JACK
KNURLED COLLAR
HANDSET PLUG
Figure 6 - Handset Replacement
Page 10
Installation and Operation
Model EA401
See: Figure 6 - Handset
Replacement