Cosel ADA750F 사용 설명서 - 페이지 9
{카테고리_이름} Cosel ADA750F에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Cosel ADA750F 11 페이지.

AC-DC Power Supplies Enclosed Type
R
Vcc
I=20mA max
External Power
Source
Connector for remote ON/OFF (Optional)
Fig.5.4 Example of use remote ON/OFF
*This connector is different if used with option -J.Refer to Fig. 5.3
for pin arrangements.
¡When external power source is in the range of 4.5 - 12.5V, cur-
rent limit resistance R is not required. However, when external
power source exceeds 12.5V, current limit resistance R must be
connected.
To calculate the current limit resistance, use the following equa-
tion:
Vcc- (1.1+RiX0.005)
R [W] =
0.005
Where ;
Vcc = External Power Source
Ri = The internal resistance (780W)
¡A wrong connection may damage the internal components of the
unit.
¡Remote ON/OFF circuit (RC (+), RC (-) ) is isolated from input,
output and FG.
¿-N1
-A type with a fi tting supporting a dedicated DIN rail.
-Consult us external view in details.
-A type in which terminal block screws are aligned vertically (op-
tion: -T).
Fig. 5.5 Din Rail Attachment
¿-W
(It is not possible to combine with option -J)
--W is available for detecting low input alarm (PF), detecting low
output voltage (LV) and operating N+1 redundancy.
-Alarm specifi cation is shown Table 5.2.
-Special harness is prepared, refer to option parts.
-Consult us external view in details.
-Each alarm (PF,LV) is isolated from input, output and FG.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
CN3*
SW
Ri
RC (+)
1
2
RC (-)
Instruction Manual
Table 5.2 Explanation of alarms
Alarm
When line voltage is abnor-
mal (low input voltage out of
PF
range), the alarm outputs from
CN3.
If the output voltage drops be-
low the rating, the alarm signal
is output from CN3.
Note : 1This becomes un-
stable in the event
of output overcur-
LV
rent (intermittent
overcurrent).
2The alarm signal is
not output for paral-
lel operation that
does not use OR
diodes.
Please consult us details.
PF +
PF -
Fig.5.6 PF internal circuit
ADA
Output of alarm
Open collector method
Good : Low
(0 - 0.8V, 1mA max)
Fail : 50V max
Open collector method
Good : Low
(0 - 0.8V, 1mA max)
Fail : 50V max
+ V
LV +
LV -
- V
Fig.5.7 LV internal circuit
ADA-15