Gardena 8898 사용 설명서 - 페이지 7

{카테고리_이름} Gardena 8898에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Gardena 8898 14 페이지. Accu shrub shears
Gardena 8898에 대해서도 마찬가지입니다: 사용 설명서 (15 페이지), 사용 설명서 (15 페이지)

Gardena 8898 사용 설명서
Disposal:
(in accordance with
RL2012/19/EC)
Disposal of
batteries:
0

6. Maintenance

DANGER!
Risk of Injury!
DANGER!
Personal Injury and
Damage to Property!
Cleaning the Accu Shears
and Oiling the Blades:

7. Trouble-Shooting

DANGER!
Risk of Injury!
Problem
Hedge is not cleanly cut
During charging socket
flashes red
During operation the charging
jack flashes yellow
Runtime too low
16
The product must not be added to normal household waste.
It must be disposed of in line with local environmental regulations.
The GARDENA Accu Shears contains lithium-ion cells that should
not be discarded with normal household waste at the end of their
life.
Li-ion
Please return the lithium-ion cells to your GARDENA dealer or
dispose of them properly at a public recycling centre.
1. Discharge lithium-ion cells
2. Remove the handle, base plate and side parts, and take the
lithium ion cells
3. Dispose of lithium-ion cells
Blades can cause injury.
v F or maintenance work, slide on the blade protection and
do not push the safety lock forward.
There is a risk of personal injury and damage to the Shears
if you clean them under running water (especially under high
pressure).
v Never clean your Shears under running water.
To increase operating time, the Accu Shears should be cleaned
and sprayed after each use.
1. Clean your Accu Shears with a damp cloth.
2. Spray shear blade with GARDENA Cleaning Spray Art. 2366.
Blades can cause serious injury.
v W hen troubleshooting, slide on blade protection and do
not push the safety lock of the Accu Shears forward.
Possible Cause
Blade blunt or damaged.
A fault has occurred during
charging.
The motor is overloaded
through a blockage of the
blades and switches off.
Blade soiled.
0
completely.
0
out of the Accu Shrub Shears.
0
properly.
Remedy
v Have blade replaced by
GARDENA-Service.
v U nplug and reinsert charging
cable. The fault will be reset.
v R emove blockage.
Start Accu Shears anew.
The fault is remedied.
v C lean and lubricate scissor
blade in accordance with the
maintenance instructions.