AlienTek T100 사용자 설명서 - 페이지 6
{카테고리_이름} AlienTek T100에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. AlienTek T100 16 페이지. Smart soldering station
ALIENTEK
5. Display description
After the power switch is turned on, the soldering station starts to display the boot UI. If there
is no access handle, prompt "No Tip", otherwise enter main UI and the soldering station works
normally. The working status of the soldering station can be divided into the following four types:
Normally: Heating and constant temperature at set temp.In the main UI, rotate or click the
encoder to enter temperature adjust UI. You can adjust the set temperature by rotating and clicking
the encoder. After the adjustment is completed, it will automatically return to the main UI.
Double-click the encoder to enter the setting menu UI, long press the encoder will return to the
main UI. When a period of time (Time①: Sleep Time) does not use the handle, does not rotate and
clicks the encoder, it goes to sleep.
Sleeping:Heating and constant temperature at sleep temp. Vibrate the handle, rotate or click
the encoder to exit the sleep state and return to the main UI. When a period of time (Time②:
Standby time) does not use the handle, does not rotate, and clicks the encoder, it enters the standby
state.
Standby:Not heated. Vibrate the handle, rotate or click the encoder to exit the standby state
and return to the main UI. The temperature of tip drops from the sleep temperature,when it drops
T100 Smart Soldering station
Fig 5.1 system flow
4
User Manual