Garmin echoMAP 70s Guide 참조 - 페이지 34

{카테고리_이름} Garmin echoMAP 70s Guide에 대한 참조을 온라인으로 검색하거나 PDF를 다운로드하세요. Garmin echoMAP 70s Guide 42 페이지. Technical reference for garmin nmea 2000 products
Garmin echoMAP 70s Guide에 대해서도 마찬가지입니다: 설치 지침 매뉴얼 (12 페이지), 참조 매뉴얼 (2 페이지), 사용자 설명서 (28 페이지), 제품 정보 (37 페이지), 사용 설명서 (28 페이지), 템플릿 (2 페이지), 적합성 선언 (6 페이지), 구성 매뉴얼 (2 페이지), 빠른 시작 매뉴얼 (4 페이지), 설치 지침 매뉴얼 (8 페이지), 소유자 매뉴얼 (38 페이지)

Garmin echoMAP 70s  Guide 참조
NMEA 2000 Checklist
• For other Garmin marine devices, select
3. Select a tank number.
4. Select OK.
Configuring the NMEA 2000 Tank Capacity
You can indicate the capacity of the fluid tank that the GFL 10 adapter is associated with.
1. From the NMEA 2000 Devices list, select the GFL 10 device.
2. Select an option:
• For most Garmin chartplotters, select
• For other Garmin marine devices, select
3. Select the tank capacity.
4. Select Done.
Calibrating the Fluid Level
To use the GFL 10 adapter, you must calibrate the fluid level of the tank that the adapter is associated with, using a minimum of two calibration
points. The greater the number of fluid calibration points, the greater the accuracy of the reading on the fluid-level gauge.
1. Turn the boat ignition key to the On position (not Start).
2. From the NMEA 2000 Devices list, select the GFL 10 device.
3. Select an option:
• For most Garmin chartplotters, select
• For other Garmin marine devices, select
4. Select the percentage of fluid currently in the tank, based on the total tank capacity.
5. Select Done.
6. Change the level of the fluid in the tank.
7. Select
Add Calibration
Point.
8. Select the percentage of fluid currently in the tank, based on the total tank capacity.
9. Select Done.
10. Repeat steps 6 through 9 to add additional, optional fluid-level calibration points.
Troubleshooting the Tank Number
If multiple GFL 10 adapters are assigned to the same NMEA 2000 fluid type, each adapter is assigned a unique tank number automatically. If
the "Invalid NMEA 2000 tank configuration" error message appears, you must assign a unique tank number to each adapter.
For example, if two adapters are assigned the NMEA 2000 fluid type value of Live Well and the error message appears, you must assign each
adapter a unique tank number.
1. From the NMEA 2000 Devices list, select the GFL 10 device.
2. Select an option:
• For most Garmin chartplotters, select
• For other Garmin marine devices, select
3. Select a tank number.
4. Select OK.
Troubleshooting the Gauge Type
When connected to a gauge, the GFL 10 adapter gauge type is set to auto Detect by default, and the adapter automatically detects the type of
gauge it is connected to. If the fluid-level reading on a connected Garmin chartplotter or marine instrument changes with the engine RPM, the
adapter may be detecting the wrong type of gauge.
Note: The fluid level changes when the boat is moving. Test the gauge-type setting when the boat is not moving.
30
Config
>
Tank
Number.
Review
>
N2K Tank
Capacity.
Config
>
N2K Tank
Capacity.
Review
>
Level Calibration
Config
>
Level Calibration
Review
>
Tank
Number.
Config
Tank
Number.
>
>
Add Calibration
Point.
>
Add Calibration
Point.
Technical Reference for Garmin NMEA 2000 Products