Alert Text
VLOC has failed (530
only)
VLOC is not responding
(530W only)
VLOC needs service
(530W only)
VLOC remote transfer
key is stuck (530W
only)
VLOC transfer key
stuck
(530W only)
Stormscope device has
failed
Stormscope heading
has failed
500W Series
Instructions for Continued Airworthiness Bell 206B
Possible Cause
The GNS 530W has detected a failure
in its VLOC receiver.
Internal system-to-system
communication between the main
processor and the VLOC receiver has
failed. Operational status of the VLOC
receiver is unknown.
The unit has detected a failure in its
VLOC receiver. The VLOC receiver
may still be usable.
The remote VLOC transfer switch is
stuck in the enabled (or "pressed")
state.
The VLOC flip-flop key is stuck in the
enabled (or "pressed") state.
The 400W- Series unit cannot
communicate with the WX-500.
The WX-500 is reporting a system
failure.
The WX-500 is reporting invalid
heading data.
Solution
Contact Garmin technical
support.
Contact Garmin technical
support.
Contact Garmin technical
support.
Try pressing the switch again
to cycle its operation.
Contact Garmin technical
support.
Try pressing the VLOC flip-
flop key again to cycle its
operation.
Contact Garmin technical
support.
Check for proper configuration
Check the wiring
Refer to the WX-500
installation manual for
additional troubleshooting
information.
Check for proper configuration
of WX-500
The failure may be within the
WX-500 or other connected
equipment.
190-01226-03 Rev. 5