alkitronic XM Series 운영 및 유지보수 매뉴얼 - 페이지 6

{카테고리_이름} alkitronic XM Series에 대한 운영 및 유지보수 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. alkitronic XM Series 12 페이지.

alkitronic XM Series 운영 및 유지보수 매뉴얼
Operation and Maintenance Manual
3. Reaction points / support positions
Safe and stable counter mounting is essential.
Improper support may lead to damage to the tool
or injury to the operator due to the high reaction
forces generating from the tool.

3.1 Reaction support

alkitronic® M-ML / Norwolf Missing Link / Z series or
XCE Link
Fig. 5
Reaction support surface (tightening)
Manually push the Link Housing against a solid object (nor-
mally the next nut). Locate a secure system component or a
stationary reaction point.
Support correct / incorrect
Correct support!
4
Punctual loadings or
sharp-edged counter
mountings may cause
damage to the housing.
1
To protect housing
during excessive use,
slide an aluminum shim
(1) between housing and
Incorrect support!
reaction point.
Fig. 6
4
4
1
Tilted reaction support out of the
support area - high hazard potential -
must be strictly avoided!
Dangerous tipping can be caused by the bolting
connection and the manual torque multiplier being
at different heights. For this situation, reduce the
maximum torque of the wrench. Before starting
work, ask your alkitronic® Partner or Alki Technik
GmbH for safe solutions.
If the tool tends to "ride up" or "creep", stop and re-
adjust the reaction area to a more solid and secure
position.
3.2
Using and positioning the alkitronic® / Norwolf
reaction torque arm (DMA)
Depending on the application, a DMA can also be
used optional.
Professional positioning of the alkitronic® / Norwolf
DMA is dependent on the joint. For individual
solutions your alkitronic® Partner or alki TECHNIK
GmbH will gladly advise you.
Fig. 7
Torque Wrench
Application Example:
The alkitronic® M-ML/ Norwolf Missing Link in plant construc-
tion when fitting a plate.
6
Fix the DMA and
screw up the safety
screws
Reaction support surface
Fig. 8