Garmin GHP 10V 설치 지침 매뉴얼 - 페이지 12
{카테고리_이름} Garmin GHP 10V에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Garmin GHP 10V 20 페이지. Marine autopilot system
Garmin GHP 10V에 대해서도 마찬가지입니다: 설치 지침 매뉴얼 (48 페이지), 소유자 매뉴얼 (28 페이지), 설치 지침 매뉴얼 (20 페이지)

Connecting an Optional GPS Device to the GHP 10V Autopilot System
To use an optional optional GPS device with the GHP 10V, either connect a NMEA 2000-compatible GPS device to the NMEA 2000 network,
or connect a NMEA 0183-compatible GPS device directly to the GHC 10.
To connect an optional NMEA 2000-compatible GPS device to your GHP 10V:
1. Add an additional T-connector (not included) for the optional GPS device you want to add to the NMEA 2000 network.
2. Connect the GPS device to the T-connector by following the instructions provided with the GPS device.
To connect an optional NMEA 0183-compatible GPS device to your GHP 10V:
1. Determine the NMEA 0183 wiring assignments of your NMEA 0183-compatible GPS device.
2. Use the GHC 10 power/data cable wiring diagrams to correctly wire your NMEA 0183-compatible GPS device.
3. Use 22 AWG twisted-pair wire for extended runs of wire.
4. Solder and cover all bare-wire connections.
Example:
GHC 10
Device
Notes:
•
Consult the installation instructions for your NMEA 0183-compatible device to identify the Transfer (Tx) A(+) and B(-) wires.
•
If your NMEA 0183-compatible device has only one transmitting wire (Tx), connect it to the brown wire (Rx/A) from the GHC 10, and
connect the green wire (Rx/B) to ground.
•
If your NMEA 0183-compatible device has only one receiving wire (Rx), connect it to the blue wire (Tx/A) from the GHC 10, and leave the
white wire (Tx/B) unconnected.
•
The yellow (CCU signal) wire must be wired to the yellow wire of the CCU cable.
1
GHC 10
Device
GHC 10 Power/Data Cable
WIRE
COLOR
Fuse
1 A
BLACK
BROWN
>
GREEN
>
BLUE
>
WHITE
>
YELLOW
Wiring the GHC 10 to a NMEA 0183-Compatible Device
Color
Fuse
Red
1 A
Black
Yellow
>
Blue
>
White
>
Brown
Green
>
-
+
Battery
WIRE
12 Vdc
FUNCTION
RED
POWER
POWER GND
NMEA GND
Tx/A (+)
Tx/B (-)
Rx/A (+)
Rx/B (-)
to CCU
Function
Power
Ground
CCU Signal
Tx/A(+)
Tx/B(-)
Rx/A(+)
Rx/B(-)
NMEA 0183-
Compatible
Device
>
>
>
>
GHP 10V Installation Instructions