Fujitsu ABT24AG 운영 매뉴얼 - 페이지 10
{카테고리_이름} Fujitsu ABT24AG에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Fujitsu ABT24AG 17 페이지. Floor console/under ceiling dual type
Fujitsu ABT24AG에 대해서도 마찬가지입니다: 운영 매뉴얼 (17 페이지), 운영 매뉴얼 (17 페이지)
TIMER OPERATION
About the PROGRAM timer
G The PROGRAM timer allows you to integrate OFF timer
and ON timer operations in a single sequence. The se-
quence can involve one transition from OFF timer to ON
timer, or from ON timer to OFF timer, within a twenty-
four hour period.
G The first timer function to operate will be the one set near-
est to the current time. The order of operation is indi-
cated by the arrow in the remote control unit's display
(OFF → ON, or OFF ← ON).
G One example of PROGRAM timer use might be to have
the air conditioner automatically stop (OFF timer) after
you go to sleep, then start (ON timer) automatically in
the morning before you rise.
SLEEP TIMER OPERATION
Instructions relating to heating (*) are applicable only to "HEAT & COOL MODEL" (Reverse Cycle).
Unlike other timer functions, the SLEEP timer is designed to set the duration of time in which the unit does not operate.
To Use the SLEEP timer
While the air conditioner is operating or stopped, press the
SLEEP button.
Both the indoor unit's OPERATION indicator lamp (red) and the TIMER indicator
lamp (green) will light.
To Change the Timer Settings
Press the SLEEP button once again and set the time using the
SET TIME buttons.
Set the time while the Timer Mode Display is flashing (the flashing will continue for
about five seconds).
button: Press to advance the time.
button: Press to reverse the time.
About five seconds later, the entire display will reappear.
About the SLEEP timer
To prevent excessive warming or cooling during sleep, the SLEEP timer function automatically modifies the thermostat setting
in accordance with the time setting. When the set time has elapsed, the air conditioner completely stops.
*During Heating operation:
When the SLEEP timer is set, the thermostat setting is
automatically lowered 1 ˚C every thirty minutes. When the
thermostat has been lowered a total of 4 ˚C, the thermostat
setting at that time is maintained until the set time has elapsed,
at which time the air conditioner automatically turns off.
SLEEP timer setting
30
minutes
10
1 °C
2 °C
3 °C
4 °C
1 hour
1 hour
30 minutes
Set time
About the ON timer
G The timer function is designed to bring your room to a
comfortable temperature by the set time; as a result, the
unit automatically begins operation before the set time
so that the room reaches the desired temperature by the
time set on the timer ("Nice-Morning Timer").
G The hotter it is in summer, or the colder it is in winter, the
earlier that operation will begin.
* During Heating Operation ....... from 45 to 10 minutes be-
During Cooling/Dry Operation ... from 20 to 10 minutes be-
During Fan Operation .............. at the set time.
To Cancel the Timer:
Use the TIMER button to select "TIMER
RESET".
The air conditioner will return to normal
operation.
To Stop the Air Conditioner During
Timer Operation:
Press the START/STOP button.
During Cooling/Dry operation:
When the SLEEP timer is set, the thermostat setting is auto-
matically raised 1 ˚C every sixty minutes. When the thermo-
stat has been raised a total of 2 ˚C, the thermostat setting at
that time is maintained until the set time has elapsed, at which
time the air conditioner automatically turns off.
SLEEP timer setting
fore set time.
fore set time.
SLEEP
TIMER
SLEEP
COOL
MASTER
SET
SET
FAN
CONTROL
TEMP
.
TIME
CONTROL
Set time
1 hour
2 °C
1 °C