FUNCTION DETAILS
Functions
1) Filter sign
2) Embedding the indoor unit in a wall
3) Cooler room temperature correction
4) Heater room temperature correction
5) Auto restart
Indoor room temperature sensor switching
6)
function
7) Remote controller signal code
8) External input control
9) Indoor unit fan control for energy saving
1) Filter sign
The indoor unit has a sign to inform the user that it is time to clean the filter. Select the time
setting for the filter sign display interval in the table below according to the amount of dust or
debris in the room. If you do not wish the filter sign to be displayed, select the setting value for
"No indication".
Setting description
Long interval
Short interval
No indication
The filter sign interval time is different according to Indoor unit type as follows.
Setting description
Standard
Long interval
Short interval
Floor
z
z
z
z
z
z
z
z
z
Function number
Standard
Floor
400 hours
1000 hours
200 hours
- (01 - 25) -
(  ... Factory setting)
Setting value
00
01
11
02
03