AEG OKO FAVORIT 676 사용 설명서 - 페이지 22

{카테고리_이름} AEG OKO FAVORIT 676에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. AEG OKO FAVORIT 676 24 페이지. Dishwasher
AEG OKO FAVORIT 676에 대해서도 마찬가지입니다: 사용 설명서 (25 페이지), 사용 설명서 (24 페이지)

AEG OKO FAVORIT 676 사용 설명서
Information for the installer
Anti-flood system — AQUA-LOCK
The dishwasher is equipped with AQUA-LOCK
anti-flood devices.
The machine has an overfiow protection which
prevents excess water from entering the
machine and a leakage protection underneath
the machine (a float in the base of the
machine). The float is activated by leakage
from the appliance. The AQUA-LOCK system
also monitors the double-skin outlet hose for
defects. In all cases the water supply to the
machine is shut off and the drain pump is
switched on. This will happen even if the
machine is switched off.
ELECTRICAL CONNECTION
WARNING — THIS APPLIANCE MUST BE
EARTHED
Please ensure that the voltage and current
indicated on the rating plate agrees with the
voltage of your electricity supply.
220/240 volts — (i.e., 220/240 V AC).
If your appliance has been equipped with a
mains lead with a moulded-on type plug, you
must comply with the following regulations:
The plug moulded on to the cord incorporates
a fuse. For replacement, use
a 13 amp BS
1362 fuse. Only ASTA approved or certified
fuses should be used. The fuse cover/carrier
must be replaced in the event of changing the
fuse. The plug must not be used if the fuse
cover/carrier is lost.
A replacement cover/car-
rier must be obtained from an electrical goods
retailer. if the socket outlets in your home are
not suitable for the plug fitted to the appliance,
then the plug must be cut off and an
appropriate one fitted. When fitting the plug
please note the following points:
IMPORTANT
THE WIRES IN THE MAINS LEAD ARE
COLOURED IN ACCORDANCE WITH THE
FOLLOWING CODE:
GREEN and YELLOW - EARTH
BLUE
— NEUTRAL
BROWN
— LIVE
22
Flooding from the machine through leakage or
overflowing has thus been eliminated. Any
remaining water in the machine is automati-
cally pumped away.
The fault can be recognised by the continu-
ous operation of the pump. In this case first
turn off the water tap, then switch off at the
power socket and remove the plug.
As the colours of the wires in the mains lead
of this appliance may not correspond with the
coloured markings identifying the terminals in
your plug, proceed as follows:
1. The wire which is coloured GREEN and
YELLOW must be connected to the EARTH
terminal in your plug, which is marked with
the letter E or by the earth symbol © or
coloured GREEN, or GREEN and YELLOW.
2. The wire which is colour BROWN
must be
connected to the LIVE terminal which is
marked with the letter L or coloured RED.
3. The wire which is coloured BLUE must be
connected to the neutral terminal which is
marked with the letter N or coloured
BLACK.
When wiring the plug, ensure that all strands
of wire are securely retained in each terminal.
Do not forget to tighten the mains lead clamp
on the plug.
Warning! A cut off plug inseried into a
13 amp socket is a serious shock hazard.
Ensure that the cut off plug is disposed off
safely.
Voltage
220/240 V AC
Fuse rating
13 amps
See rating plate for further information.